Section 7 — Handling and Storage

Handle, transport and store carefully and securely to avoid accidental knocking over or other
severe physical impacts. Do not expose to direct heat sources. Do not over-pressurize.

Section 8 — Exposure Controls/Personal Protection

Respiratory: None

Protective Gloves: Leather gloves are recommended when handling cylinders.

Eye Protection: Eye protection is recommended when handling cylinders.

Other Protective Clothing or Equipment: Safety shoes are recommended when handling cylin-
ders.

Work Hygienic Practices: Wash thoroughly after handling. Wash contaminated clothing

before reuse.

Section 9 — Physical & Chemical Properties

Appearance:

Colorless gas

Physical State:

Gas

Odor:

Odorless

Solubility in Water: 260 mg/L

Section 10 — Stability and Reactivity

Stability: Stable under normal conditions of handling and use.

Conditions to Avoid: None

Section 11 — Toxicological Information

VALUE (LD50 or LC50)

Animal

Routes

Components

>788.696 ppm/4H

Rat

Acute Inhalation

1.1.1.2.3.3.3 Heptafluoropropane

The human health hazards of this product are expected to be similar to other liquefied gases
including N2, C02, CFCs, HCFCs, and HBFCs. Therefore, direct eye or skin contact with the
liquid or cold gas can cause chilling or possibly frostbite of exposed tissues.   Inhalation of high
concentrations can be harmful or fatal due to oxygen deprivation and/or heart irregularities
(arrhythmias). Misuse of the products by deliberately inhaling high concentrations of this gas
could cause death without warning. Persons with preexisting cardiac or central nervous sys-
tem disorders may be more susceptible to effects of an overexposure.

Section 12 — Ecological Information

No ecological information is available.

Section 13 — Disposal Considerations

Dispose of waste and empty cylinders as allowed by current Local, State/Province, or Federal
laws and regulations.

Section 14 — Transport Information

Proper Shipping Name: Heptafluoropropane
ID Number: UN3296
Hazard Class: 2.2
Packing Group: N/A
Labels: Non-flammable gas
Packing Instructions: 200

18

WARNING

CONCENTRATED AGENT AND BY-PRODUCT OF APPLICATION TO FIRE ARE TOXIC. AVOID

BREATHING OF FUMES OR PROLONGED EXPOSURE. ACCIDENTAL DISCHARGE DURING

HANDLING OR INSTALLATION MAY CAUSE SERIOUS INJURY. BEFORE ATTEMPTING TO

INSTALL THIS DEVICE, READ AND COMPLY WITH INSTRUCTIONS, WARNINGS, AND

LIMITATIONS CONTAINED IN THIS MANUAL. DO NOT LIFT, CARRY, OR HANDLE BY

SENSOR VALVE/DETECTOR. THE SENSOR/VALVE DETECTOR IS VISUALLY DESCRIBED IN

FIGURE 4 OF THIS MANUAL. DO NOT DROP. KEEP AWAY FROM HEAT. KEEP AWAY FROM

CHILDREN.

WARNING

PRIOR TO PERFORMING MAINTENANCE WITHIN THE PROTECTED

COMPARTMENT, ALWAYS INSTALL SAFETY PIN EXTINGUISHER SYSTEM

TO AVOID ACCIDENTAL DISCHARGE. AT COMPLETION OF MAINTENANCE,

REMOVE SAFETY PIN FROM TRIGGER ASSEMBLY, AND STORE IN

HOLDING TIE LOCATED ON CYLINDER.

OWNER’S MANUAL & INSTALLATION GUIDE

SEA-FIRE FM-200

®

 AUTOMATIC FIRE EXTINGUISHER MANUAL: PART NO.123-194

3

Содержание FD1000A

Страница 1: ...FIRE EXTINGUISHERS INSTALLATION INSTRUCTIONS OWNER S MANUAL THIS MANUAL IS AN INTEGRAL PART OF THE SYSTEM AND AS SUCH THE EXTINGUISHER MUST BE INSTALLED AND MAINTAINED ACCORDINGLY U S COAST GUARD APPROVED FM APPROVED No 162 029 237 0 READ AND COMPLY WITH THESE INSTRUCTIONS WARNINGS AND LIMITATIONS BEFORE INSTALLING SUITABLE FOR USE FG MODELS 0 F 18 C TO 130 F 54 C FD MODELS 20 F 7 C TO 130 F 54 C ...

Страница 2: ... DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES Metalcraft Sea Fire Marine Inc has taken reasonable care in preparing this document how ever since the use of this information and the conditions of use of the product are not within the control of Metalcraft Sea Fire Marine Inc it is the user s obligation to determine the con ditions of safe use of this product The information in this document is of...

Страница 3: ...nd or heart irregularities arrhythmias Misuse of the products by deliberately inhaling high concentrations of this gas could cause death without warning Persons with preexisting cardiac or central nervous sys tem disorders may be more susceptible to effects of an overexposure Section 12 Ecological Information No ecological information is available Section 13 Disposal Considerations Dispose of wast...

Страница 4: ...t the combustion reaction cannot sustain itself CAUTION IN CASE OF EXTINGUISHER DISCHARGE DO NOT RUSH TO OPEN THE PROTECTED COMPARTMENT LET THE EXTINGUISHING AGENT WORK FOR SEVERAL MINUTES HAVE A PORTABLE EXTINGUISHER AVAILABLEAND USE CARE WHEN OPENING THE COMPARTMENT AVOID BREATHING FIRE RELATED FUMES OR VAPOR NOTE It is important to retain the designed vapor concentration within the compartment ...

Страница 5: ... 2 0 AMPS AT 28 VDC For applications requiring larger load capacities see optional equipment section in this manual or contact factory ENGINES AND POWERED VENTILATION BLOWERS DIESEL ENGINES Continued operation of diesel engine s and or powered ventilation units will deplete the extinguishing agent and may cause a fire re flash Diesel engine s must be automatically shutdown upon extinguisher discha...

Страница 6: ...26 150 3 5 4 2 5 4 2 4 6 5 2 9 5 2x17 0 132x476 FD175A FD175M 151 175 4 2 5 0 6 5 2 9 7 6 3 4 5 2x17 0 132x476 FD200A FD200M 176 200 5 0 5 7 7 6 3 4 8 7 3 9 5 2x17 0 132x476 FD225A FD225M 201 225 5 7 6 4 8 7 3 9 9 7 4 4 5 2x17 0 132x476 FD250A FD250M 226 250 6 4 7 1 9 7 4 4 10 8 4 9 6 9x18 0 175x463 FD275A FD275M 251 275 7 1 7 8 10 8 4 9 11 9 5 4 6 9x18 0 175x463 FD300A FD300M 276 300 7 8 8 5 11 9...

Страница 7: ...0 APPROVED FOR VERTICAL OR HORIZONTAL MOUNTING MODEL FD 1050 thru FD 1500 FOR VERTICAL MOUNTING ONLY Cubic Feet CU FT Kilograms KG Cubic Meters CU M Inches IN Pounds LBS Millimeters MM V M E O R U O T N N I T L C I Y A N L G 14 Step 5 Locate bracket in desired position Vertical Sensor Valve Detector Head Up or Horizontal Figure 2 Using the bracket as a template mark and drill holes in bulkhead and...

Страница 8: ...6 or 7 a Before attaching cable to the cylinder check that the cylinder bracket is located correctly and firmly mounted b With the cylinder strapped in its bracket pass the cable jacket ferrule completely through the hole in the cylinder manifold This will allow the necessary cable flexibility needed for inserting the offset end of the flexible shaft into the actuator lever After connecting the sh...

Страница 9: ...l and making to determine the applicable DOT specification The discharged extinguisher may be refilled upon the prepaid return of the discharged system Contact factory or authorized dealer for detail RETURN TO UNITED STATES SEA FIRE MARINE Division of Metalcraft Inc 9331 A Philadelphia Road Baltimore Maryland 21237 USA EUROPE SEA FIRE EUROPE LTD Unit 7 io Centre Stephenson Road Fareham Hampshire P...

Страница 10: ...icate the ability to discharge the agent but not the quantity of extinguishing agent The cylinder less bracket must be weighed on at least a semiannual basis and be replaced immediately if gross weight has decreased by quantity noted on the specification label Never paint or obstruct the cylinder manifold or sensor valve detector as this will adversely affect its operating characteristic FD models...