SN12I HEAT PUMP NON-PROGRAMMABLE THERMOSTAT 

 

 

  Installation and Operation Manual 

 

 

 

SPECIFICATIONS 

 

Power Supply: 

20VAC-30VAC 50-60HZ 

Terminal Load: 

1.0A per terminal, 3.0A maximum total load   

Setpoint Temp. Range:  45ºF to 90ºF (7ºC to 32ºC) 
Accuracy: 

+/- 1ºF or +/- 0.5ºC 

Dimensions: 

6.0” W X 4.7” H X 1.1” D   

Color: 

White   

FEATURES 

 

•  Large LCD display with backlight, continuous backlight option 
•  Independent heat and cool setpoints 
•  Simultaneous display of room temperature, setpoint, and current time   
•  Fan switch with ON and AUTO functions 
•  Permanent user setting retention during power loss - no batteries are required*   
•  Operates on 24VAC 
•  Air filter service indicator 
•  Low battery indicator 
•  Temperature calibration 
•  Configurable compressor short cycling protection 
•  Compatible with 2 heat/1 cool heat pump systems with emergency heat 

*

Two “AA” batteries required to maintain clock function.   

IMPORTANT SAFETY INFORMATION

   

•  Use a professional contractor to install this thermostat.   
•  Read all of the information in this manual before installing this thermostat.   
• 

WARNING! Electrical Shock Hazard.

 

Always turn off power at the main power source by 

removing the fuse or switching the circuit breaker to the 

“OFF” position before installing, 

removing, cleaning, or servicing this thermostat.   

• 

WARNING! Do not install on voltages higher than 30 VAC. 

This is a 24VAC 

low-voltage thermostat. 

 

•  All wiring must conform to local and national building and electrical codes and ordinances.   
•  Do not short (jumper) across terminals on the gas valve or at the system control to test 

installation. This will damage the thermostat and void the warranty.   

•  Do not run the system in cooling if the outside temperature is below 50ºF (10ºC). This may 

damage the air conditioning system.   

•  Replace batteries when the low battery icon flashes. 
•  Clean or replace the air filter when “SERVICE FILTER” begins flashing. 
•  Use this thermostat only as described in this manual.   

Содержание SN12I

Страница 1: ...Safety Information 1 Remove the Old Thermostat 3 Install the New Thermostat 4 Configuration 5 Configuration Menu Chart 6 Parameters 6 System Check 8 Basic Thermostat Operation 9 Troubleshooting 10 Wa...

Страница 2: ...n clock function IMPORTANT SAFETY INFORMATION Use a professional contractor to install this thermostat Read all of the information in this manual before installing this thermostat WARNING Electrical S...

Страница 3: ...vice Reminder Time Day Setting Low Battery Icon Configuration Compressor Lockout Delay SET TO AM MON SERVICE FILTER CONFIG COMP DELAY ON AUTO AUX EMH Figure 1 THERMOSTAT BUTTONS AND SWITCHES Figure 2...

Страница 4: ...OFF position 3 Remove the cover of the old thermostat This should expose the wires 4 Label the wires from the existing thermostat using the enclosed wire markers and record in the chart below before r...

Страница 5: ...ing screws and anchors provided mount the thermostat base loosely to the wall or junction box See Figure 3B 6 Place a level against the bottom of the base and adjust until level then tighten the screw...

Страница 6: ...the battery compartment Install two fresh AA alkaline batteries in the battery compartment CAUTION Installing batteries backwards can damage the thermostat Be sure to match positive and negative ends...

Страница 7: ...compressor from short cycling you can select the minimum length of time the compressor will turn off between cycles from 0 to 5 minutes in 1 minute increments When a compressor lockout delay occurs CO...

Страница 8: ...the number of days is also displayed in the upper left corner of the LCD A selection of 00 will deactivate this feature When SERVICE FILTER is displayed in EMH HEAT or COOL mode it can be cleared by...

Страница 9: ...ow setpoint and turn off at setpoint The auxiliary heat will activate when the room temperature is below the setpoint by the auxiliary heat offset value AU plus heating cycle rate value HC as establis...

Страница 10: ...e SL ow cooling cycle rate is selected the thermostat will call for cooling when the room temperature is 1 5 F 1 C above setpoint and turn off at setpoint 3 When the thermostat calls for cooling will...

Страница 11: ...e If no buttons are pressed within 15 seconds the thermostat will exit to normal operation 4 In filter review mode press and hold the and buttons at the same time to reset the amount of time until the...

Страница 12: ...itations or ex clusion may not a pply to you INTERNATIONAL REFRIGERATION PRODUCTS CO INC LIMITED WARRANTY POLICY INTERNATIONAL REFRIGERATION PRODUCTS CO INC Langhorne PA 19047 www irproducts biz INTE...

Отзывы: