Sea & Sea Leak Sentinel V5 XB Скачать руководство пользователя страница 2

Thank you for choosing Leak Sentinel V5 XB, the premier pre-dive vacuum leak detection 
system for underwater camera housings. 
 
Please read this manual carefully before installing and using the Leak Sentinel V5 XB 
 
1.

 

Safety precautions 

 
Never  dive  or  immerse  the  housing  in  any  water  without  the  protective  cap.  The  rubber 
valve is not watertight and serves only to hold the vacuum during the evacuating process. 
Diving  or  immersing  the  housing  without  the  protective  cap  will  result  in  flood  and/or 
damage  to  your  housing,  camera  and  Leak  Sentinel.  Replace  the  protective  cap 
immediately after acheiving pre-dive testing vacuum.   
 
Follow  the  standard  pre-dive  testing  procedure  immediately  after  installation  to  confirm 
there is no leak. All units are tested thoroughly prior to shipping. In case  your test shows 
there is a leak, re-check the seal between the Leak Sentinel and the housing. It is the sole 
responsibility  of  the  user  to  ensure  the  tightness  between  the  Leak  Sentinel  and  the 
housing. Vivid Housings will not be held responsible for any damage that may result from 
the faulty installation and/or use of the product. If a problem persists, please do not use 
the product and contact the manufacturer. 
 
When screwing or unscrewing the protective cap and/or pump cap, always hold the valve 
body with the opposite hand to ensure the housing body does not turn, loosening it from 
the camera housing. A loose Leak Sentinel housing can cause a camera housing to leak. 
It is not advisable to dive without a negative vacuum on the camera housing with the Leak 
Sentinel installed. While diving with a negative vacuum on the housing should not result in 
any  damage,  it  is  advised  to  always  test  the  water-tightness  of  the  housing  and  Leak 
Sentinel prior to diving. After all, peace of mind, knowing the camera housing is secure, is 
the  reason  for  installing  the  Leak  Sentinel  in  the  first  place.  One  should  plan  the  dive  so 
there  is  time  for  pre-dive  testing  by  performing  the  pre-dive  procedures  listed  below  in 
Section 4.  It may also be noted that many leaks occur in the rinse tank; this is because the 
o-rings  seal  better  under  pressure  and  there  is  very  little  water  pressure  in  a  rinse  tank.  

Содержание Leak Sentinel V5 XB

Страница 1: ...XB Pre dive and dive leak detection system for underwater camera housings with TEMPERATURE COMPENSATION LOW BATTERY INDICATION OVERNIGHT FUNCTION RESET FUNCTION USER MANUAL www vividhousings com info...

Страница 2: ...Vivid Housings will not be held responsible for any damage that may result from the faulty installation and or use of the product If a problem persists please do not use the product and contact the ma...

Страница 3: ...lve before attempting to equalize the pressure If there is even a small droplet of water left near the valve it will be sucked into the device and onto the circuit board which may damage the component...

Страница 4: ...referencing the figure above Do not disassemble the valve body and the adapter there are no user serviceable parts inside the valve body and opening the compartment may result in the damage to the cir...

Страница 5: ...ding on your housing type remove the lid from the accessory port Nauticam Aquatica Isotta Hugyfot Seacam Nexus Subal etc the bulkhead cap Sea Sea the control gland Ikelite or the bulkhead itself Sea S...

Страница 6: ...b Push the cable attached to the device through the accessory port from the outside...

Страница 7: ...tighten snugly by hand using more force than you would to screw the protective cap but not so much as to break anything In case of non threaded ports consult your housing s manual for details about i...

Страница 8: ...id installing the holder directly at the bottom of the housing if not absolutely necessary to keep the battery dry in case of spillage etc If there is no other option adding an absorbent soldering cle...

Страница 9: ...finger is too hard 3 Push the red wire into the hole on the plastic lid on the terminal Keep pushing until the wire hits the back wall about 3mm 4 Put the board on the flat hard surface and press the...

Страница 10: ...green alternating LED is indicating that a pressure change is detected and the circuit is active 6 After the number of strokes needed to achieve the proper vacuum which depends on the housing volume t...

Страница 11: ...Leak Sentinel from the camera housing to rinse the housing and or Leak Sentinel To remove the Leak Sentinel from the housing during rinsing procedures could cause the housing to flood 2 After thoroug...

Страница 12: ...e To do so just switch the Leak Sentinel off by pressing the rubber valve on off button without equalizing the pressure When the circuit is switched on again by again pressing the rubber valve on off...

Страница 13: ...h water after every salt water dive Soak longer if the salt had a chance to dry Clean the outside of the device with soft cloth or if more thorough cleaning is required with a mildly soaped wet cloth...

Страница 14: ...ly a dab of silicone grease between the lip and metal part of the housing the lip seals against Rotate the valve pressing lightly downwards to spread the grease evenly Greasing the valve will ensure a...

Страница 15: ...res in Chapter 7 and correctly reinsert the battery After reinserting the battery try to switch the device on again If the battery is inserted in the holder correctly and the Leak Sentinel s LED is no...

Страница 16: ...nt disk is attached to the bottom of the rubber valve inside the valve body with silicone grease The transparent disk facilitates switching the unit on and off Without the disk switching the unit on a...

Отзывы: