4. Pre-Dive Procedures and Operation 
 

1.

 

Remove  the  protective  cap  by  unscrewing  the  cap  in  a  counter-clockwise  motion, 
being sure to hold the Leak Sentinel body to avoid loosening the Leak Sentinel from 
the camera housing. 

2.

 

Gently  press  the  translucent  button  on  the  rubber  valve  in  a  downward  motion, 
until the switch clicks, which can be felt by the finger. 

3.

 

The red LED will give one long blink, then will start blinking steadily, indicating the 
circuit is active. At this time, ambient pressure is measured and memorized by the 
unit. 

4.

 

Detach  the  tubing  from  the  pump  cap.  Screw  the  pump  cap  into  the  valve  body. 
Attach the tubing back to the pump cap. 

5.

 

Start pumping by pulling in and out on the pump handle, or by simply pressing the 
pump’s  ON  button  in  case  you  are  using  the  Leak  Sentinel  electric  pump.The  LED 
should  start  alternating  with  a  red  and  green  LED  light.  The  red  and  green 
alternating  LED  is  indicating  that  a  pressure  change  is  detected  and  the  circuit  is 
active. 

6.

 

After the number of strokes needed to achieve the proper vacuum, which depends 
on  the  housing  volume,  the  green  LED  will  perform  one  long  blink,  then  keep 
blinking  steadily.  Stop  pumping  after  two  consecutive  green  blinks  after  the  long 
green blink. 

7.

 

Detach the tubing from the pump cap and remove the pump cap. 

8.

 

Replace  and  tighten  the  protective  cap.    Be  sure  the  protective  cap  o-ring  is 
lubricated with a small amount of o-ring grease. 
Now,  observe  the  LED.  If  the  green  LED  still  blinks  after  15-20  minutes    then  no 
leakage is present and the housing is ready for immersion in water. If the green LED 
stops  blinking  and  the  alternating  red-green  or  red  LED  starts  blinking,  there  is  a 
leak, so it is not safe for  any type of immersion in water. If there is a leak, then a 
procedure for locating and eliminating the cause of the leak should be followed.  Be 
sure and test the camera housing again with the Leak Sentinel after any repairs are 
made to the camera housing and/or its o-rings. 

Содержание Leak Sentinel V5 XB

Страница 1: ...XB Pre dive and dive leak detection system for underwater camera housings with TEMPERATURE COMPENSATION LOW BATTERY INDICATION OVERNIGHT FUNCTION RESET FUNCTION USER MANUAL www vividhousings com info...

Страница 2: ...Vivid Housings will not be held responsible for any damage that may result from the faulty installation and or use of the product If a problem persists please do not use the product and contact the ma...

Страница 3: ...lve before attempting to equalize the pressure If there is even a small droplet of water left near the valve it will be sucked into the device and onto the circuit board which may damage the component...

Страница 4: ...referencing the figure above Do not disassemble the valve body and the adapter there are no user serviceable parts inside the valve body and opening the compartment may result in the damage to the cir...

Страница 5: ...ding on your housing type remove the lid from the accessory port Nauticam Aquatica Isotta Hugyfot Seacam Nexus Subal etc the bulkhead cap Sea Sea the control gland Ikelite or the bulkhead itself Sea S...

Страница 6: ...b Push the cable attached to the device through the accessory port from the outside...

Страница 7: ...tighten snugly by hand using more force than you would to screw the protective cap but not so much as to break anything In case of non threaded ports consult your housing s manual for details about i...

Страница 8: ...id installing the holder directly at the bottom of the housing if not absolutely necessary to keep the battery dry in case of spillage etc If there is no other option adding an absorbent soldering cle...

Страница 9: ...finger is too hard 3 Push the red wire into the hole on the plastic lid on the terminal Keep pushing until the wire hits the back wall about 3mm 4 Put the board on the flat hard surface and press the...

Страница 10: ...green alternating LED is indicating that a pressure change is detected and the circuit is active 6 After the number of strokes needed to achieve the proper vacuum which depends on the housing volume t...

Страница 11: ...Leak Sentinel from the camera housing to rinse the housing and or Leak Sentinel To remove the Leak Sentinel from the housing during rinsing procedures could cause the housing to flood 2 After thoroug...

Страница 12: ...e To do so just switch the Leak Sentinel off by pressing the rubber valve on off button without equalizing the pressure When the circuit is switched on again by again pressing the rubber valve on off...

Страница 13: ...h water after every salt water dive Soak longer if the salt had a chance to dry Clean the outside of the device with soft cloth or if more thorough cleaning is required with a mildly soaped wet cloth...

Страница 14: ...ly a dab of silicone grease between the lip and metal part of the housing the lip seals against Rotate the valve pressing lightly downwards to spread the grease evenly Greasing the valve will ensure a...

Страница 15: ...res in Chapter 7 and correctly reinsert the battery After reinserting the battery try to switch the device on again If the battery is inserted in the holder correctly and the Leak Sentinel s LED is no...

Страница 16: ...nt disk is attached to the bottom of the rubber valve inside the valve body with silicone grease The transparent disk facilitates switching the unit on and off Without the disk switching the unit on a...

Отзывы: