Installation Instructions for the

ME Jr. plus 2 Infrared Alarm System

SK-3690
(Optional) “Where it’s At Light”

SK-808ME
ME Jr. plus 2 (8) Port Splitter Box

SK-109
Telephone Modular “Shunt Plug”

SK-847-x
Extension (Connects Alarm Module
to Splitters & Splitters to Splitters)

SK-800ME

I

ME Jr. plus 2 Alarm Module with Key Switch & Infrared Remote

Battery Installation:

1. Remove the screw that restricts the battery 

door from opening using a phillips head 
screwdriver as shown in Fig. 1.

2. Insert the key and turn it to the disarmed 

position (the key cannot be removed in the 
disarmed position). 

Note: The battery door will not open without the
key in the lock and in the disarmed position.
3. Remove the battery door.
4. 
Before installing batteries, plug the (SK-195) 

AC/DC Power Supply into the Alarm Module 
jack marked Pwr. Input as shown in Fig. 2.

5. Install (4) fresh “C” Cell Alkaline batteries 

following (+) and (-) polarity shown in Fig. 3.

VERY IMPORTANT! When installing batteries,
always follow the polarity indicated on the 
battery holder.

6. Close the door as shown in Fig. 4. The horn 

will “Double Chirp” until the door is securely
closed. 

7. Replace the battery door retaining screw as 

shown in Fig. 5. (If the key is in the disarmed 
position for 1-1/2 minutes, the horn will  
Single Chirp” every 15 seconds to indicate 
that the unit is in the disarmed mode.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

SK-882
Infrared Remote Transmitter

SK-800ME

I

Series

Содержание ME Jr. plus 2 SK-800MEI Series

Страница 1: ...will not open without the key in the lock and in the disarmed position 3 Remove the battery door 4 Before installing batteries plug the SK 195 AC DC Power Supply into the Alarm Module jack marked Pwr Input as shown in Fig 2 5 Install 4 fresh C Cell Alkaline batteries following and polarity shown in Fig 3 VERY IMPORTANT When installing batteries always follow the polarity indicated on the battery h...

Страница 2: ...tters from both circuits does not exceed 10 If all 10 splitters are chained to a single circuit a Shunt Plug must be installed in the other circuit A Shunt Plug must also be installed in the last splitter of each chain Special Note Place the ME Jr plus 2 in the Key Disarm Mode to install splitters and sen sors The Key Disarm Mode prevents the unit from Automatically Arming after 4 minutes After ar...

Страница 3: ...et from the other side of the adhesive pad and position the Rectangular Sensor over the flat area of the product previously cleaned Press the sensor firmly into place to insure a proper bond as shown in Fig 7 above The light on the sensor will light RED when the sensor is applied correct ly to the product Clean Wipe Dry Rectangular Adhesive Pad SK 905 Fig 6 Fig 7 Remove Adhesive Backing Sensor Con...

Страница 4: ... with a small phillips head screw shown in Fig 11 3 Arrange the Dip Switches into any configuration to create your own encoded signal Make sure the Dip Switches match on the Alarm Module and the Infrared Remote Transmitter Note It is highly recommended that you change the Dip Switch settings from the factory default This protects the system from being tampered by anyone with an infrared remote set...

Отзывы: