MASTER
UNLOCK
1, 2 UNLOCK
3, 4, 5 UNLOCK
1, 2 LATCH
3, 4, 5
LATCH
CCTV
DOORBELL
Relay 2
Jumper across
1
st
& 2
nd
pins)
Relay 1
Jumper across
2nd & 3rd pins)
Ex: User Unlock Authorization
USER UNLOCK AUTHORIZATION
Placing jumpers across the first 3 sets of pins (MASTER UNLOCK, 1,2 UNLOCK or 3,4,5 UNLOCK) determines
which relay (if any) each User Group is authorized to activate. When a valid code is entered, the door will remain
unlocked for the programmed Door Open Time. (See Programming Door Open Time pgs 13-14)
Example:
1. Placing a jumper across the 2
nd
and 3
rd
pins of the
“MASTER UNLOCK” option allows the master code to
activate (unlock) Relay #1.
2. Placing a jumper across the 1
st
and 2
nd
pins of the
“1,2 UNLOCK” option allows User Code 1 and User
Code 2 to activate Relay #2.
3. Leaving a jumper off the “3,4,5 UNLOCK” option
prevents User Code 3, User Code 4 and User Code 5
from activating either relay.
LATCHING AUTHORIZATION
Placing jumpers across the 4
th
and 5
th
set of pins (1,2 LATCH or 3,4,5 LATCH) determines which relay (if any)
each User Group is authorized to manually latch.
How to Latch
When a valid code is entered on the keypad followed by “7”, the Latch Authorization relay for that particular User
Group will energize and remain energized until a valid code followed by “7” is entered again.
Ex: Latching Authorization
P:\INSTALLATION INST\Access Control\INST-931.vsd 0505 Page 9
Example:
1. Placing a jumper across the 1
st
and 2
nd
pins of the “1, 2 LATCH”
option allows User 1 and User 2 to Latch Relay #2.
2. Leaving a jumper off the “3,4,5 LATCH” option prevents User 3,
User 4 and User 5 from latching either relay.
Note:
Because the Master Code is primarily used to program User
codes, the Master Code does not have Latching Authorization.
CCTV/Doorbell Setup
Placing jumpers across the 6
th
or 7
th
set of pins (CCTV or DOORBELL)
determines which relay (if any) will be used to activate a CCTV or Doorbell.
CCTV Operation
If either relay is configured to activate a CCTV, any key press on the
Keypad triggers a 10 second output.
Ex: CCTV Setup
*
Doorbell Operation
If either relay is configured to activate a doorbell, pressing at the Keypad triggers a 1 second output. (Doorbell
only functions with KP-4U, KP-3U, and KP-3Y.
TAMPER ALARM LOCKOUT
A person attempting to gain entry by guessing the code and pushing 25 wrong digits will cause the 931 EntryCheck
™
to go into tamper alarm mode. The Keypad will beep constantly for 30 seconds during which time the door will remain
locked and no keypad functions can be performed.