SYSTEM PROGRAMMING
OVERVIEW OF SYSTEM CODE PROGRAMMING
1. There are TWO levels of codes for the 931 EntryCheck
™
system.
a.
The Master Code (used to open the door and for programming User Codes)
b.
User Codes (used by personnel to open the door)
2. All codes must be 3 to 8 digits.
3. All codes must be different from each other.
4. 5-Pad Keypads have two digits on each pad. The system reads these numbers as the same.
For example: 1-3-5-7-9 is the same as 2-4-6-8-0.
5. Do not program codes, which are part of other codes.
For example: User Code 1 1-2-3-4-5 and User Code 2 1-2-3
6. During programming, the system resets after 5 seconds if a number is not entered. Do not let more than 5
seconds elapse between entries or the system will reset and you will have to start over.
OVERVIEW OF THE MASTER CODE
Knowledge of the Master Code is the highest privilege granted to a user of the 931 EntryCheck
™
system. There is
only one master code, which is used to program each of the 5 User Codes. The factory default Master Code,
“1-3-5-7-9”, can be used for initial programming but should be changed to a unique 3 to 8 digit code.
The Master Code can be configured to activate either Relay #1 or Relay #2 depending on how the system hardware
is set up (Setting Relay Options pgs 8-9). However, the Master Code cannot be configured to Latch either relay.
PROGRAMMING THE MASTER CODE
To Program/Change the Master Code:
1. Select a 3 to 8 digit code that will be used for the Master Code.
___ ___ ___ ___ ___ ___ ___ ___
2. Locate the Control Module, remove the cover and locate the “PROGRAM” switch on the circuit board.
3. Press the PROGRAM switch once. (The Keypad will beep rapidly 4 times) Once the PROGRAM switch has
been pressed, you have 2 minutes to begin programming.
4. At the Keypad, enter 1-1-1-9 to open the memory (you will hear three rapid beeps) and immediately enter your
new Master code. (Do not let more than five seconds elapse between entries or the system will reset!!!)
5. After entering your new code, wait five seconds for the 3 reset beeps.
P:\INSTALLATION INST\Access Control\INST-931.vsd 0505 Page 10
OVERVIEW OF USER CODES
There are a total of 5 User codes (also called Secondary Codes) that can be programmed into the 931 EntryCheck
™
.
User Codes can vary in length from 3 to 8 digits. Each User Code is programmed into one of 5 User Locations.
These Locations are as follows:
User #
User Location
User Code 1
1-1-1
User Code 2
1-1-3
User Code 3
1-1-5
User Code 4
1-1-7
User Code 5
1-1-9
Once a User Code has been programmed into a User Location, the User Code can be easily changed or deleted
from the system.
Latching and User Code Unlocking Authorization is determined by how each relay is configured. (Setting Relay
Options pgs 8-9)