background image

920PW WIRING & GROUNDING

See Fig. 3 for an example of a basic door installation.  The 
920PW is mounted adjacent to the door.  An electric door 
strike is mounted in the door jamb to release the door lock.  
A magnetic switch is mounted on top of the door jamb for 
detecting when the door is open.  The access host 
controller is located at a maximum distance of 300ft of the 
keypad reader, depending on the reader voltage provided.

Refer to the Fig. 4 or Fig. 5 for wiring details.

To avoid damage to the unit from static discharges, this 
unit must be connected to a proper earth ground.  Connect 
the green earth ground wire to a good earth grounding 
point.  Suggested wiring size is 18 AWG for earth ground.

P:\INSTALLATION INST\Access Controls\INST-920\INST-920PW.vsd     Rev A     09-17     Page 2

Fig. 3  Basic Door Installation  

Fig. 5 Installation Wiring to IPDCE Single-Door Controller

6 wires for    

KP Reader    

SDC IP Pro™ Single Door Controller 

or 3

rd

Party Access Control

2 wires for

Door Sensor

2 wires for

Strike Power

920PW

Keypad

FRONT

YELLOW
“PROGRAM”
INDICATOR

RED/GREEN
POWER/ACCESS
INDICATOR

KEYPAD

PROX 

Antenna

2 wires for

Remote

Release

BEEPER 
LEVEL 
JUMPER
(JP1)

DTRX

JP1

BACK

9-PIN WIRING

HARNESS

ANTI-

TAMPER

SWITCH

MASTER CODE
RESET JUMPER
(JP2)

JP
2

WIRING 

HARNESS

Fig. 4 Wiring Harness Connections

RED

BLK

WHT
GRN

ORG

YEL

BLU

PNK

VIO

}

C

N/O

N/C

Tamper

Buzzer

SDC P/N:  

IPDCE or IPDSE

SENSE
CLOCK

DATA

+

12V

0V

RED
GREEN

Wire

 

Color

Designation

RED

+VDC

 

(5

16V)

BLACK

GND

WHITE

WIEGAND

 

D1

GREEN

WIEGAND

 

D0

ORANGE

GREEN

 

LED

 

CONTROL

YELLOW

BUZZER

 

CONTROL

BLUE

TAMPER

 

(N.O.)

SALMON

TAMPER

 

(COM)

VIOLET

TAMPER

 

(N.C.)

920

 

PW

 

Wiring

 

Harness

 

Connections

5.750

1.375

3.000

Grn Wire
To earth ground

earth
ground

Отзывы: