P:\INSTALLATION INST\Access Controls\INST-926\INST-926.vsd     Rev -

01-18     Page 7

Mounting

Use the provided enclosure holes to mount the 926 keypad to a 

wall, pilaster or gooseneck pedestal 

post

.  Use supplied hardware or other appropriate hardware suitable for your specific mounting 

surface.  Clean any debris out of the enclosure that may cause a short.  

If the keypad is used to activate a gate operator, mount the keypad a minimum of 6' from the 
gate and gate operator to avoid contact with the movement of the gate upon activation.

POST

MOUNT

SURFACE

MOUNT

1" DIA

4X 3/8" DIA

2-7/8"

2-7/8"

Содержание 926 EntryCheck

Страница 1: ...ormally open pushbutton or wireless switch to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access...

Страница 2: ...s Program the first user code Step 1 Enter 9 123456 Enter the program mode default master code Step 2 Enter 03 4 Set the entry code length to 4 digits Step 3 Enter 21 5 Set the main relay activate time to 5 sec Step 4 Enter 01 001 9876 9876 1 PIN code 9876 is assigned to User 001 to momentarily activate the main relay Step 5 Enter Exit programming mode Adding additional user codes Once the code le...

Страница 3: ...ring TO POWER SUPPLY KEYPAD POWER 12 or 24 VOLTS AC OR DC RED BLACK AUXILIARY RELAY 2 AMPS 28VDC MAX NC NO COM ORG BLK BLK WHT BRN YEL FAIL SECURE CONNECTION FAIL SAFE CONNECTION MAIN RELAY 5 AMPS 28VDC MAX NC COM NO ORANGE WHITE YELLOW BLACK PINK SALMON GREEN GRAY BLACK VIOLET BLACK BLUE DOOR POSITION SWITCH N C REQUEST TO EXIT SWITCH N O COMMON OUTPUT 4 OUTPUT 3 NOT USED COMMON SENSE REQUEST TO ...

Страница 4: ...ory The green indicator will light when the new code is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the code number i e 0001 do not need to be entered when programming a new code The 926 will internally add any zeros to fill digits determined by the ent...

Страница 5: ...activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 13 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door...

Страница 6: ... During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Seconds Output time in seconds 1 60 99 Toggle Mode Beep Sounds on Keystrokes Default Yes Selects whether or not the keypad beeps as each k...

Страница 7: ... Use supplied hardware or other appropriate hardware suitable for your specific mounting surface Clean any debris out of the enclosure that may cause a short If the keypad is used to activate a gate operator mount the keypad a minimum of 6 from the gate and gate operator to avoid contact with the movement of the gate upon activation POST MOUNT SURFACE MOUNT 1 DIA 4X 3 8 DIA 2 7 8 2 7 8 ...

Отзывы: