Beep Sounds During Auxiliary Relay

Default: No

Selects whether or not the keypad beeps during Auxiliary Relay 
activation.

Press: 42 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3

Default: No

Selects whether or not the keypad beeps during Output #3 
activation.

Press: 43 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4 

Default: No

Selects whether or not the keypad beeps during Output #4 
activation.

Press: 44 # 

Sound

#  

Sound=1 for Yes, =0 for No

Anti-Pass Back Time

Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is 
used.

Press: 51 # Minutes #  

Minutes=Time in minutes (2-4), 0=No Anti-passback

RESETTING KEYPAD

Master Reset

CAUTION:  Performing a master reset will clear the 
entire memory of the 926 and return all programmable 
options to the factory default values.  ALL ENTRY 
CODES WILL BE ERASED. NOTE:  The Master Code will 
NOT be reset.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys 
down until the red indicator starts flashing

STEP 4

Release the keys.  The red and yellow indicators will 
remain lit until the process is complete, then the 
yellow indicator will go out.

Resetting the Master Code

STEP 1

Remove the 926 from the wall and disconnect 

power from the keypad.

STEP 2 

Locate & Remove jumper at JP2.  Reference page 2.  

STEP 3

Re-apply power.  You will get a single beep and 
the yellow LED will flash momentarily.

STEP 4

Replace jumper on JP2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

Beep Sounds During Main Relay

Default:  No

Selects whether or not the keypad beeps during Main Relay 
activation.

Press: 41 # 

Sound

#  

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time

Default:  02 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 24 # 

Seconds

#  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds on Keystrokes

Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

#  

Sound=1 for Yes, =0 for No

P:\INSTALLATION INST\Access Controls\INST-926\INST-926.vsd     Rev -

01-18     Page 6

Selects mode for Keypad LED Backlight

Default: 30 Seconds

Selects whether or not the keypad back light stays OFF, lights for 30 
seconds when activated or stays ON.

Press: 52 # Output #  

0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON 

Solid-state Output #3 On-time

Default:  02 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 23 # 

Seconds

#  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds Anti-Tamper Activation 

Default: No

Selects whether or not the keypad beeps during Anti-Tamper 
switch activation.

Press: 45 # 

Sound

#  

Sound=1 for Yes, =0 for No

Changing the Beeper Sound Level

The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.

Keypad Lockout Count

Default: 3 Attempts

Sets the number or incorrect entry code attempts allowed 
before the keypad “locks out” for 60 seconds.

Press: 50 # Attempts #  

Attempts=Number of attempts before lockout (2-7)

*Refer to Option 13 to Enable Lockout Relay

Door Ajar Timer

Default:  60 Seconds

Sets the amount of time the door may be held open after an 
authorized access.  The DOOR AJAR output will activate after the 
time expires.

Press: 25 # 

Seconds

#  

Seconds=Held open time in seconds (1-60)

Содержание 926 EntryCheck

Страница 1: ...ormally open pushbutton or wireless switch to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of the relays or solid state outputs to shunt alarm contacts on the access door gate preventing the triggering of an alarm when an authorized access...

Страница 2: ...s Program the first user code Step 1 Enter 9 123456 Enter the program mode default master code Step 2 Enter 03 4 Set the entry code length to 4 digits Step 3 Enter 21 5 Set the main relay activate time to 5 sec Step 4 Enter 01 001 9876 9876 1 PIN code 9876 is assigned to User 001 to momentarily activate the main relay Step 5 Enter Exit programming mode Adding additional user codes Once the code le...

Страница 3: ...ring TO POWER SUPPLY KEYPAD POWER 12 or 24 VOLTS AC OR DC RED BLACK AUXILIARY RELAY 2 AMPS 28VDC MAX NC NO COM ORG BLK BLK WHT BRN YEL FAIL SECURE CONNECTION FAIL SAFE CONNECTION MAIN RELAY 5 AMPS 28VDC MAX NC COM NO ORANGE WHITE YELLOW BLACK PINK SALMON GREEN GRAY BLACK VIOLET BLACK BLUE DOOR POSITION SWITCH N C REQUEST TO EXIT SWITCH N O COMMON OUTPUT 4 OUTPUT 3 NOT USED COMMON SENSE REQUEST TO ...

Страница 4: ...ory The green indicator will light when the new code is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the code number i e 0001 do not need to be entered when programming a new code The 926 will internally add any zeros to fill digits determined by the ent...

Страница 5: ...activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 13 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door...

Страница 6: ... During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Seconds Output time in seconds 1 60 99 Toggle Mode Beep Sounds on Keystrokes Default Yes Selects whether or not the keypad beeps as each k...

Страница 7: ... Use supplied hardware or other appropriate hardware suitable for your specific mounting surface Clean any debris out of the enclosure that may cause a short If the keypad is used to activate a gate operator mount the keypad a minimum of 6 from the gate and gate operator to avoid contact with the movement of the gate upon activation POST MOUNT SURFACE MOUNT 1 DIA 4X 3 8 DIA 2 7 8 2 7 8 ...

Отзывы: