the science of yield

•  THIS PRODUCT MUST BE INSTALLED IN 

ACCORDANCE WITH THE APPLICABLE 
INSTALLATION CODE BY A PERSON FAMILIAR 
WITH THE CONSTRUCTION AND OPERATION OF 
THE PRODUCT AND THE HAZARDS INVOLVED

ATTENTION

INSTALLING THE FIXTURE

INSTALLATION PREP

MOUNTING THE LIGHT FIXTURE

ELECTRICAL CONNECTION

CONTROLING THE LIGHT

1. 

Switch off main voltage

2.  Refer to your light plan.  Arrange boxed light 

fixtures in specified mounting locations. 

3.  Remove the fixture from the packaging and 

check contents.

4.  Gather any additional tools and/or hardware that 

may be required to mount the fixture.

The Dragon XL 1200/LX 600 is designed to hung using the mounting brackets at either end 
of the fixture’s cowling.  There are four mounting hole options, each of which will aim the 
fixture at a different angle.  The optional aiming angles are; 0° 15°, 30°, and 45°.
See Figure 1 for additional details. 
When mounting the Dragon XL1200 or XL600 fixtures in an array a minimum distance of 8 
inches side to side and a minimum distance of 1 inch end to end must be maintained.   When 
mounting next to a ceiling or wall, movable partitions, and the like, insure a minimum distance 
of 1.5 inches is between the fixture and the ceiling and 8 inches between the fixture and the 
wall and other adjacent objects.

Dragon XL 1200/XL 600 is equipped with a 7ft power cord, 
terminated with a standard wall pug (NEMA 5-15).
Simply plug the light in and you are ready to go.
Always ensure that fixtures are compliant with local building codes. 

 
When routing the fixture power cord ensure that;
- The cord is not concealed or extended through a wall, floor, 

ceiling, or other parts of the building structure.
- The cord is not located above a suspended ceiling or 

dropped ceiling.
- The cord is not permanently affixed to the building structure.
- The cord is routed so that it is not subject to strain and is 

protected from physical damage.
- The cord is visible over its entire length.

Dragon XL 1200/XL 600 is equipped with four 
independent channels of LEDs (White 2700K, White 
4200K, White 6000K, and Red 600 nm).  Each 
channel can be independently dimmed from 0% to 100%.   
Channel dimming can be adjusted on-demand using the 
mobile app (See Mobile App Instructions for details) or 
by setting up an embedded schedule in the light (See 
Scheduling Instructions for details).

Figure 1: Fixture 

mounting detail

To ensure safe operation of the lighting equipment it is 
necessary to control the temperature of the room by 
mechanical ventilation or cooling system to below the 
maximum ambient operating temperature of 40ºC (104ºF).

SINGLE 

PHASE CORD 

TERMINATION

DOUBLE 

PHASE CORD 

TERMINATION

BLACK

Line

WHITE

Neutral

GREEN

Ground

BLACK

Line

WHITE

Line

GREEN

Ground

Содержание DRAGON XL 1200

Страница 1: ...the science of yield USER MANUAL INSTALLATION GUIDE 4641 East Ivy Street Mesa AZ 85205 480 256 0017 info scynce ag SCYNCE AG...

Страница 2: ...on carefully before installing and or operating the product We recommend you keep this manual on hand for future reference For further information please contact SCYNCE 4641 East Ivy Street Mesa AZ 85...

Страница 3: ...e possibility of injury to the user and or damage to the product should the user not perform the procedures as described A note alerts the user to potential problems which may occur if a procedure is...

Страница 4: ...r standard please refer to https www scynce ag product warranty for full details Ambient Operating Temp 40 40 C Certification Tested to UL1598 UL8750 UL8800 CSA C22 2 NO 250 0 08 CSA C22 2 NO 250 13 W...

Страница 5: ...e 120 optic offers intensity radiated energy that is slightly brighter on the outside of the beam When hanging fixtures with 120 optic it is important to overlap the beams to achieve an even intensity...

Страница 6: ...on or maintenance work Do not open or disassemble the fixture it contains no serviceable parts inside Opening the fixture can be dangerous and will void the warranty Never look directly into the light...

Страница 7: ...nd 8 inches between the fixture and the wall and other adjacent objects Dragon XL 1200 XL 600 is equipped with a 7ft power cord terminated with a standard wall pug NEMA 5 15 Simply plug the light in a...

Страница 8: ...te lens is always clean In the event that the product is defective or damaged contact the dealer from whom you purchased the fixtures or SCYNCE directly Never switch on a defective or damaged fixture...

Страница 9: ...he fixture emits too little light when compared to the other fixture s Reload default settings Contact the installer and have the wiring checked If the issue persists contact supplier for assistance F...

Страница 10: ...4641 East Ivy Street Mesa AZ 85205 480 256 0017 info scynce ag SCYNCE AG 10 the science of yield PRODUCT DIMENSIONS 117 178 171 122 6X 15 1232 1126 74 131 2X 185...

Страница 11: ...4641 East Ivy Street Mesa AZ 85205 480 256 0017 info scynce ag SCYNCE AG 11 the science of yield PRODUCT DIMENSIONS 116 8 171 117 159 6X 18 185 671 131 565 60...

Отзывы: