42
teStinG laBoratory
manUfactUrer
moDel
iSSUe Date
inVeStiGatinG officer
teSt report
reSUltS
conclUSion
Hrl technology
Seguin Duteriez
europa 7 evolution
14.12.2015
Steve marland
HcmG/15/098
the appliance particulate emissions factor was 1.2/kg of hard wood that
complies to AS/NZS 4014.1 and the average efficiency of the appliance
for all burn rates was 60%.
the europa 7 evolution plus solid fuel appliance complies with the
requirements of aS/nZS 4014/4013 (2014).
europa 7 partiCulate emissions, power output and effiCienCy test
teSt reSUltS
teStinG laBoratory
manUfactUrer
moDel
iSSUe Date
inVeStiGatinG office
reSUltS
conclUSion
Hrl technology
Seguin Duteriez
multivision 8000
02.11.2015
Steve marland
testing of the maximum power(kW) output of the Visio 8 insert solid fuel
appliance was performed at the high burn rate prescribed in aSnZS4013
(2014) on the 24th of november 2015. the appliance produced a
maximum Heat output of 25.9kW
exemption from testing the Visio 8 insert solid fuel appliance should be
claimed under section 1.2.3 (b) of aS/nZS4013 (2014) as the maximum
heat output from combustion is greater than 25kW when fired at the
prescribed high burn rate and that the appliance is intended for space
heating by means of transferring heat to the living are by ducted hot air.
multiVision 8000 applianCe power output test
Содержание Multivision 800