SCS TB-9079 Скачать руководство пользователя страница 1

TB-9079

 Page 1 of 17

© 2017 DESCO INDUSTRIES, INC.

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

WS Aware Monitor

Installation, Operation and Maintenance

March 2017

Description

The SCS WS Aware Monitor is a dual workstation 

continuous monitor for operators, ESD worksurfaces 

and metal tools.  It continuously monitors the 

path-to-ground integrity and body voltage of two 

operators, as well as the path-to-ground integrity for two 

conductive or dissipative worksurfaces and two metal 

tools.  It also continuously monitors for electromagnetic 

interference (EMI) on two metal tools which may cause 

electrical overstress (EOS) damage.  The WS Aware 

Monitor eliminates the need for periodic testing and 

record keeping of wrist straps.

Made in the

United States of America

 USER GUIDE TB-9079

The WS Aware Monitor is designed with digital signal 

processing technology for true continuous monitoring 

(versus pulsed or intermittent) of wrist strap functionality 

(path-to-ground and presence of 1 megohm resistor) 

and operator safety according to accepted industry 

standards without capacitance variations from personnel 

or environment.  Digital signal processing technology 

uses dual-wire wrist straps to apply an ultra-low test 

voltage of 0.05V onto the operator for the handling of 

sensitive components.
The WS Aware Monitor features operator body voltage 

detection.  It will alarm if the operator generates or 

comes in contact with voltage that would be dangerous 

to an ESD susceptible item.
The WS Aware Monitor continuously monitors two metal 

tools for electromagnetic interference (EMI).  EMI can 

cause equipment lockups and malfunction.  The WS 

Aware Monitor will alarm if EMI is detected.  Each WS 

Aware Monitor is calibrated with accepted procedures 

and standards traceable to the National Institute of 

Standards and Technology (NIST) and includes a 

certificate of calibration.
ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.”  Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.”  Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily.  However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”
The WS Aware Monitor and its accessories are 

available as the following item numbers:

Item

Description

770061

WS Aware Monitor, with Standard Remotes

770062

WS Aware Monitor, with Big Brother 

Remotes

770064

Power Adapter, 100-240VAC Input, 7.5VDC 

1.5A Output, All Plugs

CTE701

Workstation Monitor Checker

CTA242

Operator Remote, Standard

CTA243

Operator Remote, Big Brother

CTA245

Replacement Wrist Strap Jack PCB

770055

SMP Software

Figure 1.  SCS 770061 WS Aware Monitor with Standard 

Remotes

Figure 2.  SCS 770062 WS Aware Monitor with Big 

Brother Remotes

Содержание TB-9079

Страница 1: ...erator generates or comes in contact with voltage that would be dangerous to an ESD susceptible item The WS Aware Monitor continuously monitors two metal tools for electromagnetic interference EMI EMI...

Страница 2: ...into a database for on going quality control purposes SMP allows you to pinpoint areas of concern and prevent ESD events Quantifiable data allows you to see trends become more proactive and prove the...

Страница 3: ...a metal tool for proper conductive resistance and electromagnetic interference EMI Use 25 28 AWG wire to connect the metal tool to this terminal I Monitored Tool 2 Terminal Monitors a metal tool for p...

Страница 4: ...or remote connectors located on the left side of the WS Aware Monitor 5 Route the mini DIN operator remote cables from the left side of the WS Aware Monitor to their respective operator remotes Connec...

Страница 5: ...re not included Operator Remote Operator Remote Cable WS Aware Monitor Left Side Grounded Metal Tool NOTE Worksurface must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Viny...

Страница 6: ...N SMP must be installed to a PC prior to using this procedure DYNAMIC IP PROCEDURE 1 Verify that the Ethernet cable is securely connected to your network and WS Aware Monitor The LEDs on the Ethernet...

Страница 7: ...est 909 627 9634 Website StaticControl com 5 A message will appear and display Starting SMP Server Click the SMP Server icon located in the Windows taskbar 6 SMP Server will now indicate Active server...

Страница 8: ...rial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 8 Open SCS SMP Admin 9 The window for SMP Server Admin will appear 1 unassigned is representative of the WS Aw...

Страница 9: ...d NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 10 Enter a building name and then click the OK button 11 The building name will appear on the navigation pane in SMP Server Adm...

Страница 10: ...Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 13 Enter a floor name and then click the OK button 14 The floor name will appear on the navigation pane in SMP Server Adm...

Страница 11: ...st 919 718 0000 West 909 627 9634 Website StaticControl com 16 Enter a line name and then click the OK button 17 The line name will appear on the navigation pane in SMP Server Admin 18 Click on the li...

Страница 12: ...mployee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 19 The serial number for the WS Aware Monitor will appear Click attach 20 The W...

Страница 13: ...ES INC Employee Owned SCS 926 JR Industrial Drive Sanford NC 27332 East 919 718 0000 West 909 627 9634 Website StaticControl com 21 Open SCS SMP Client 22 Verify that the WS Aware Monitor was added to...

Страница 14: ...adapter until cleaning is finished Replacing the Operator Remote s Wrist Strap Jacks Should the operator remote s wrist strap jacks begin to show wear and tear damage they can be replaced using the S...

Страница 15: ...tions Power Power Adapter 100 240VAC 50 60 Hz Output 7 5VDC 1 5A Output Plug Polarization Center Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L Operator Wrist Strap Dual Wire Amount Monitored...