Safety Information

Read, understand, and follow all safety information 

contained in this user guide prior to installation and use 

of the SCS Wrist Strap and Ground Monitor.  Retain this 

guide for future reference.

Intended Use

This user guide covers the Wrist Strap and Ground 

Monitor.  The Wrist Strap and Ground Monitor has two 

input jacks for monitoring impedance and voltage on a 

dual conductor wrist strap.  It monitors either one or two 

metal grounds in a workstation. The Wrist Strap and 

Ground Monitor operates from a universal AC power 

adapter.  These systems are typically installed on a 

machine with multiple tools or on a work bench used for 

ESD-sensitive electronic assembly or repair.
The systems must be installed as specified in this user’s 

guide and are intended for use in an indoor commercial/

industrial environment.  The systems have not been 

evaluated for other uses or locations.

Warning

To reduce the risks associated with hazardous voltage, 

which if not avoided could result in electrical shock 

related injury; the risks associated with environmental 

contamination, which if not avoided could result in 

environmental contamination related injury; and the risk 

associated with false test results, which if not avoided 

could result in property damage:

Read, understand and follow all safety information

contained in this user guide for installation and use.

Retain this guide for future reference.

To reduce the risks associated with hazardous volt-

age, which if not avoided could result in electrical shock 

related injury:

Replace power adapter if damaged with SCS

provided power adapter only.

Do not modify or attempt to service the power

adapter or use it if damaged.

Use the power adapter in an indoor dry location only.

Caution

To reduce the risks associated with environmental 

contamination which, if not avoided, could result in minor 

or moderate injury:

Dispose of monitor in accordance with all applicable

local and government regulations.

Notice

To reduce the risks associated with property damage:

Monitor must be checked periodically to verify each

monitor circuit is functioning correctly.

The SCS Wrist Strap and Ground Monitor requires

a suitable ground to function properly.  Refer to the

proper section of this User Guide for information on

connecting to a suitable electrical ground point.

Do not use the Wrist Strap and Ground Monitor  as a

primary method of electrical grounding – this device

is intended to monitor the ground connection only.

Regulatory Information

FCC 

Note: This equipment has been tested and found to 

comply with the limits for a Class A digital device, 

pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide a reasonable protection against 

harmful interference when the equipment is operated in 

a commercial environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction 

manual, may cause harmful interference to radio 

communications. Operation of this equipment in a 

residential area is likely to cause harmful interference 

in which case the user will be required to correct the 

interference at their own expense. 

�������

to this device shall not be made without the 

���������������������������

void the authority granted under Federal Communication 

Rules and Industry Canada Rules permitting the 

operation of this device.

ICES Statement

This Class A digital apparatus complies with Canadian 

ICES-003.

Cet appareil numérique de la classe A est conforme à la 

NMB-003 du Canada.

WEEE Statement

The following information is only for EU-member States: 

The mark shown to the right is in compliance with Waste 

Electrical and Electronic Equipment Directive 2002/96/

EC (WEEE). The mark indicates the requirement NOT 

to dispose the equipment as unsorted municipal waste, 

but use the return and collection systems according to 

local law.

CE Statement

Meets CE (European Confomity) requirements.

cULus Statement

Meets UL Safety Requirements.

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Содержание TB-9029

Страница 1: ...allows continuous monitoring for excessive voltage on each operator The Wrist Strap and Ground Monitor is available in one model Item Description 773 Wrist Strap and Ground Monitor with World Wide Power Adapter SCS offers the following accessories for the Wrist Strap and Ground Monitor Item Description 2368 Dual Conductor Fabric Adjustable Wristband 2360 Dual Conductor Coil Cord 5 2370 Dual Conduc...

Страница 2: ...indicates the resistance limit without a voltage being generated on the person at the same time The green LED indicates a proper connection of the operator A green LED plus a blinking red LED will indicate if there is a body voltage generated the operator may still be connected properly The green LED is off when a dual conductor ground cord is not plugged into the jack Enabling and Disabling Audib...

Страница 3: ...sistance alarm level see the CTE701 User Guide Connect the red tip of the checker to the ground monitoring terminal i e G1 or G2 Press the Fail button on the checker The red LED of the corresponding ground of the monitor should remain on Press the Pass button on the checker the corresponding light on the monitor should be green Repeat these steps for all enabled ground monitoring inputs The checke...

Страница 4: ...o the identified locations Be sure to connect the monitoring inputs to different physical locations than those points used for their grounding Person Voltage and Resistance Monitor Plug the dual conductor ground cord of the wrist strap into the jack on the front of the unit If the wrist strap is worn properly a green LED will come on otherwise red LED will be on In order to provide good ground con...

Страница 5: ...or in accordance with all applicable local and government regulations Notice To reduce the risks associated with property damage Monitor must be checked periodically to verify each monitor circuit is functioning correctly The SCS Wrist Strap and Ground Monitor requires a suitable ground to function properly Refer to the proper section of this User Guide for information on connecting to a suitable ...

Страница 6: ...y SCS in writing this information represents SCS best knowledge and belief based upon information provided by third party suppliers to SCS Part or Component Name Hazardous Substances or Elements Pb Hg Cd CrVI PBB PBDE Termination in capacitor 0603 X O O O O O Solder in diode X O O O O O Finish in diode X O O O O O Terminations in PCBs X O O O O O Terminations in resistors 0603 X O O O O O Plating ...

Отзывы: