TB-9029

 Page 4 of 6

© 2015 DESCO  NDUSTRIES,  NC.

Employee Owned

Specifications

Ground Impedance 

Alarm Level

1 to 20 ohms

Wrist Strap Alarm -

Body Voltage

±2.5V on operator

Wrist Strap Alarm -

Operator Loop 

Resistance

10 megohms on operator (plus 

two 1 megohm resistors in the 

end of the ground cord that 

attaches to the wristband)

Output Signal Level

Logic 1 (+5V) if below selected 

resistance level (all “pass”)

Logic 0 (0V) if above selected 

resistance level (any failure or 

power loss)

Note: This is for both process 

tools and wrist strap monitoring.

Visual Alarm 

Indicator (LED)

Green: OK

Red: Fault Condition

Note: Operator LEDs red and 

green will not illuminate if wrist 

strap is not plugged into jack.

Audible Alarm

Buzzer fault condition if enabled

Operating 

Environmental 

Range

Temperature: 50 to 110ºF (10 to 

43ºC)

Humidity: 75% R.H. maximum

Dimensions

2.42” W x 2.45” L x 0.85” H

(61mm W x 62mm L x 22mm H)

Power Adapter

100-240VAC

50-60 Hz

Output: 12VDC @ 1.5A

Output Plug Polarization: 

Center Positive

Output Plug: 5.5 mm O.D. x 2.1 

mm I.D. x 9.5 mm L

Functional Operation

Ground Resistance Monitor

Connect the ground wire to a known good electrical

ground point.

Connect the output wire to the tool if you intend to

use it, otherwise leave it open.

Connect the ground monitor inputs to the identified

locations.  Be sure to connect the monitoring inputs

to different physical locations than those points used

for their grounding.

Person Voltage and Resistance Monitor 

Plug the dual conductor ground cord of the wrist strap 

into the jack on the front of the unit.  If the wrist strap 

is worn properly, a green LED will come on; otherwise 

red LED will be on.  In order to provide good ground 

connection, the wrist strap must be worn tightly and the 

green light on the SCS Wrist Strap and Ground Monitor 

is an indication of that. 
If for whatever reason, while properly connected, the 

operator developed excessive body voltage (in excess 

of ± 2.5 Volts in any polarity), the green LED may still be 

on, but the red LED will blink without alarm sound.  No 

LED is on if a dual conductor ground cord is not plugged 

into the jack.

Maintenance

Replacement and Removing Input Wrist Strap Dual 

Conductor Input Jack 

If the wrist strap input jack begins to show wear after 

heavy usage, the input jack can be replaced by ordering 

the SCS 

CTA252

 Replacement Wrist Strap Jacks.  

Remove the input jack in the unit by removing the 

locking collar and two screws on front cover.  Slide the 

printed circuit board outside of the unit and unplug the 

pin connector with input jack board.  Plug in new input 

jack board assembly and carefully slide the board back 

into the housing.  Replace front cover and locking collar 

on the input jack.

Figure 4.  SCS CTA252 Replacement Wrist Strap Jacks

Содержание TB-9029

Страница 1: ...allows continuous monitoring for excessive voltage on each operator The Wrist Strap and Ground Monitor is available in one model Item Description 773 Wrist Strap and Ground Monitor with World Wide Power Adapter SCS offers the following accessories for the Wrist Strap and Ground Monitor Item Description 2368 Dual Conductor Fabric Adjustable Wristband 2360 Dual Conductor Coil Cord 5 2370 Dual Conduc...

Страница 2: ...indicates the resistance limit without a voltage being generated on the person at the same time The green LED indicates a proper connection of the operator A green LED plus a blinking red LED will indicate if there is a body voltage generated the operator may still be connected properly The green LED is off when a dual conductor ground cord is not plugged into the jack Enabling and Disabling Audib...

Страница 3: ...sistance alarm level see the CTE701 User Guide Connect the red tip of the checker to the ground monitoring terminal i e G1 or G2 Press the Fail button on the checker The red LED of the corresponding ground of the monitor should remain on Press the Pass button on the checker the corresponding light on the monitor should be green Repeat these steps for all enabled ground monitoring inputs The checke...

Страница 4: ...o the identified locations Be sure to connect the monitoring inputs to different physical locations than those points used for their grounding Person Voltage and Resistance Monitor Plug the dual conductor ground cord of the wrist strap into the jack on the front of the unit If the wrist strap is worn properly a green LED will come on otherwise red LED will be on In order to provide good ground con...

Страница 5: ...or in accordance with all applicable local and government regulations Notice To reduce the risks associated with property damage Monitor must be checked periodically to verify each monitor circuit is functioning correctly The SCS Wrist Strap and Ground Monitor requires a suitable ground to function properly Refer to the proper section of this User Guide for information on connecting to a suitable ...

Страница 6: ...y SCS in writing this information represents SCS best knowledge and belief based upon information provided by third party suppliers to SCS Part or Component Name Hazardous Substances or Elements Pb Hg Cd CrVI PBB PBDE Termination in capacitor 0603 X O O O O O Solder in diode X O O O O O Finish in diode X O O O O O Terminations in PCBs X O O O O O Terminations in resistors 0603 X O O O O O Plating ...

Отзывы: