AC/DC Adapter Connection

Connect the circular plug of the power adapter into the 

power jack on the back of the unit.

Mounting

Determine the mounting location of the Wrist Strap 

and Ground Monitor.  Attach the unit using one of the 

following recommended methods:

Screws

Dual Lock Reclosable Fastener

Note: The unit can be mounted upside down from the 

current orientation of the front and back covers.  If you 

wish to change the orientation, rotate the printed circuit 

board and covers 180 degrees.  This will allow the unit 

housing to be mounted from the wider plate with screw 

slots.

Operation

Ground Impedance Alarm Level

Use the set switch and select through a combination 

of LED patterns on the front of the monitor to set the 

alarm level.  The alarm level can be set to 1-10 ohms in 

1 ohm increments.  It can also be set to 10-20 ohms in 

2 ohm increments.  The two monitoring lines are set to 

the same selected impedance value.  If the measured 

impedance on a line is lower than the setting, a green 

LED will remain illuminated for that line(s).  If the 

impedance is higher than the preset level, a red LED 

and audible alarm are activated for that line(s).  Their 

alarm duration will be on momentarily to prevent missing 

a short increased resistance event.  If the impedance 

level remains above the preset alarm level, the red LED 

and audible sound remains on.
Note: A wire must be attached from the SCS Wrist Strap 

and Ground Monitor (GND terminal) to an approved 

ground point to monitor the grounding of process tools 

correctly.

Output Signal Level

The output connector provides a logic 1 (+5V) when all 

grounds are within the limits and the unit is powered on.  

The output connector provides a logic 0 (0V) if any of the 

monitored grounds or wrist strap fail or power to the unit 

is lost.

Person Voltage and Resistance Monitor

The alarm level is monitored when a person is wearing 

a dual conductor wrist strap assembly and plugged into 

the front jack.  There is a short hold on the body voltage 

alarm so that it is not missed.  The unit will respond 

to either a positive or negative voltage.  The alarm is 

activated when the wrist strap is worn too loosely and 

the loop resistance level is exceeded.  The red LED 

indicates the resistance limit without a voltage being 

generated on the person at the same time.  The green 

LED indicates a proper connection of the operator.  A 

green LED plus a blinking red LED will indicate if there 

is a body voltage generated; the operator may still be 

connected properly.  The green LED is off when a dual 

conductor ground cord is not plugged into the jack.

Enabling and Disabling Audible Alarm

The audible alarm can be enabled or disabled by 

momentarily pressing a recessed miniature push-button 

“Set” switch located on the back of the unit while the 

monitor’s power is on.  Use a paper clip to press the 

switch.  One short beep on power up means that the 

sound is disabled.  A series of two short beeps means 

that the sound is enabled.

Enabling or Disabling Monitoring of Ground Lines

In some instances, both of the two ground points in the 

tool do not need to be monitored.  This procedure will set 

up the number of ground lines (G1, G2) that will be used, 

so that there is no need to put jumpers or shunts on 

the unused ground monitoring inputs.  The AC Adapter 

should not be plugged in at this time.

Attach the “GND” line to ground.

Attach the monitor line(s) (G1, G2) to the ground that

has been determined to use. Do not plug any wires

into those ground monitor inputs that will be unused.

Press and hold the “Set” button using the end of a

paper clip. While the button is pressed inward, plug

in the AC Adapter and then release the “Set” button.

Wait then for ~30 seconds. The SCS  Wrist Strap

and Ground Monitor will beep during this time. After

this, it will produce one beep and will automatically

disable the lines to which nothing was connected.

You can repeat this procedure whenever a change

in monitoring of the number of ground lines is

required.

Setting Impedance Alarm Levels

By default, the SCS Wrist Strap and Ground Monitor is 

set at the factory to 10 ohms alarm level.
If you wish to change the alarm level to your 

specifications, follow this procedure to set the 

impedance alarm level for all channels (G1, G2).

Repeat the steps above in Enabling or Disabling

Monitoring of Ground Lines section.

Right after the beeping stops, continue pressing the

“Set” button until the impedance level is matched.

When the beeping stops, the left four LEDs allow for

setting of resistance value.  G1 & G2 red LEDs are

upper location and G1 & G2 green LEDs are lower.

Select the ground resistance value by repeatedly

Figure 2. Rear view of Wrist Strap and Ground Monitor 

Содержание TB-9029

Страница 1: ...allows continuous monitoring for excessive voltage on each operator The Wrist Strap and Ground Monitor is available in one model Item Description 773 Wrist Strap and Ground Monitor with World Wide Power Adapter SCS offers the following accessories for the Wrist Strap and Ground Monitor Item Description 2368 Dual Conductor Fabric Adjustable Wristband 2360 Dual Conductor Coil Cord 5 2370 Dual Conduc...

Страница 2: ...indicates the resistance limit without a voltage being generated on the person at the same time The green LED indicates a proper connection of the operator A green LED plus a blinking red LED will indicate if there is a body voltage generated the operator may still be connected properly The green LED is off when a dual conductor ground cord is not plugged into the jack Enabling and Disabling Audib...

Страница 3: ...sistance alarm level see the CTE701 User Guide Connect the red tip of the checker to the ground monitoring terminal i e G1 or G2 Press the Fail button on the checker The red LED of the corresponding ground of the monitor should remain on Press the Pass button on the checker the corresponding light on the monitor should be green Repeat these steps for all enabled ground monitoring inputs The checke...

Страница 4: ...o the identified locations Be sure to connect the monitoring inputs to different physical locations than those points used for their grounding Person Voltage and Resistance Monitor Plug the dual conductor ground cord of the wrist strap into the jack on the front of the unit If the wrist strap is worn properly a green LED will come on otherwise red LED will be on In order to provide good ground con...

Страница 5: ...or in accordance with all applicable local and government regulations Notice To reduce the risks associated with property damage Monitor must be checked periodically to verify each monitor circuit is functioning correctly The SCS Wrist Strap and Ground Monitor requires a suitable ground to function properly Refer to the proper section of this User Guide for information on connecting to a suitable ...

Страница 6: ...y SCS in writing this information represents SCS best knowledge and belief based upon information provided by third party suppliers to SCS Part or Component Name Hazardous Substances or Elements Pb Hg Cd CrVI PBB PBDE Termination in capacitor 0603 X O O O O O Solder in diode X O O O O O Finish in diode X O O O O O Terminations in PCBs X O O O O O Terminations in resistors 0603 X O O O O O Plating ...

Отзывы: