TB-9055

 Page 2 of 6

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

 

Power Adapter Connection

Connect the circular plug of the power adapter into the 

power jack on the back of the unit.

Mounting

Determine the mounting location of the Wrist Strap 

and Ground Monitor.  Attach the unit using one of the 

following recommended methods:

• 

Screws

• 

Dual Lock Reclosable Fastener

Note: The unit can be mounted upside down from the 

current orientation of the front and back covers.  If you 

wish to change the orientation, rotate the printed circuit 

board and covers 180 degrees.  This will allow the unit 

housing to be mounted from the wider plate with screw 

slots.

Operation

Ground Impedance Alarm Level

Use the set switch and select through a combination 

of LED patterns on the front of the monitor to set the 

alarm level.  The alarm level can be set to 1-10 ohms in 

1 ohm increments.  It can also be set to 10-20 ohms in 

2 ohm increments.  The two monitoring lines are set to 

the same selected impedance value.  If the measured 

impedance on a line is lower than the setting, a green 

LED will remain illuminated for that line(s).  If the 

impedance is higher than the preset level, a red LED 

and audible alarm are activated for that line(s).  Their 

alarm duration will be on momentarily to prevent missing 

a short increased resistance event.  If the impedance 

level remains above the preset alarm level, the red LED 

and audible sound remains on.
Note: The Wrist Strap and Ground Monitor must be 

grounded in order to properly monitor the ground 

integrity of metal tools.

Person Voltage and Resistance Monitor

The alarm level is monitored when a person is wearing 

a dual conductor wrist strap assembly and plugged into 

the front jack.  There is a short hold on the body voltage 

alarm so that it is not missed.  The unit will respond 

to either a positive or negative voltage.  The alarm is 

activated when the wrist strap is worn too loosely and 

the loop resistance level is exceeded.  The red LED 

indicates the resistance limit without a voltage being 

generated on the person at the same time.  The green 

LED indicates a proper connection of the operator.  A 

green LED plus a blinking red LED will indicate if there 

is a body voltage generated; the operator may still be 

connected properly.  The green LED is off when a dual 

conductor ground cord is not plugged into the jack.

Enabling and Disabling Audible Alarm

The audible alarm can be enabled or disabled by 

momentarily pressing a recessed miniature push-button 

“Set” switch located on the back of the unit while the 

monitor’s power is on.  Use a paper clip to press the 

switch.  One short beep on power up means that the 

sound is disabled.  A series of two short beeps means 

that the sound is enabled.

Enabling or Disabling Monitoring of Ground Line

In some instances, the monitor’s tool ground channel 

may not be needed.  This procedure will disable the 

GND1 terminal.  The power adapter should not be 

plugged in at this time.

• 

Ground the monitor using the ground terminal at the 

back of the unit

• 

Ensure that nothing is connected to the GND1 

terminal

• 

Press and hold the “Set” button using the end of 

a paper clip.  While the button is pressed inward, 

connect the power adapter and then release the 

“Set” button.

• 

Wait for approximately 30 seconds. The Wrist Strap 

and Ground Monitor will beep during this time.  After 

this, it will produce one beep and will automatically 

disable the GND1 terminal to which nothing 

was connected.  You can repeat this procedure 

whenever the need to disable or enable the GND1 

terminal is required.

Setting Impedance Alarm Levels

By default, the Wrist Strap and Ground Monitor is set at 

the factory to 10 ohms alarm level.  Follow the procedure 

below to change this setting.

• 

Repeat the steps above in Enabling or Disabling 

Monitoring of Ground Line section.

• 

Right after the beeping stops, continue pressing 

the “Set” button until the desired impedance level is 

acheived.  See the following table.

• 

When the beeping stops, the four left most LED’s 

will allow for the setting of the resistance value.  The 

GND red LED is located at the top; the green LED is 

located at the bottom.

• 

Select the ground resistance value by pressing the 

“Set” button to advance the resistance limit.  Turn 

the LED’s on or off as indicated in the following 

table.

• 

Save the desired setting by not pressing the “Set” 

switch for about 7 seconds.