CTC337 Wrist Strap and Ground Monitor

Installation, Operation and Maintenance

April 2016

 USER GUIDE TB-9055

Description

The SCS CTC337 Wrist Strap and Ground Monitor can 

be used in work areas or other locations to monitor 

the ground impedance of metal ground connection in 

process tools including but not limited to semiconductor, 

disk drive, flat panel and electronic equipment 

manufacturing environments.  Ground impedance 

monitoring can be used for one metal ground point, such 

as within a tool.  The Wrist Strap and Ground Monitor 

can be used to monitor the impedance-to-ground and 

voltage level on two persons wearing dual-wire wrist 

straps.  The unit incorporates green and red LEDs and 

an audible alarm.

Ground Impedance Monitor

 – Continuously monitors 

for ground impedance on one channel that is connected 

to one process tool.

Operator Connection

 – The Wrist Strap and Ground 

Monitor provides continuous monitoring of operator 

connection to the monitor via loop resistance check of 

operator’s physical presence using a dual wire wrist 

strap.

Voltage on Person Wrist Strap Monitor

 – The Wrist 

Strap and Ground Monitor has one additional feature 

that allows continuous monitoring for excessive voltage 

on each operator.

The Wrist Strap and Ground Monitor is available in one 

model:

Item

Description

CTC337-WW

Wrist Strap and Ground Monitor, with 

World Wide Power Adapter

SCS offers the following accessories for the Wrist Strap 

and Ground Monitor:

Item

Description

CTA252

Replacement Jack PCB, CTC337 Wrist 

Strap and Ground Monitor

CTE701

Workstation Monitor Checker

CTA212

Power Adapter, 100-240VAC Input, 12VDC 

1.5A Output, All Plugs

Packaging

1  Wrist Strap and Ground Monitor

1  Monitor Ground Cord (Green and Yellow)

1  Power Adapter, 12VDC, with interchangeable plugs

  (North America, UK/Asia, Europe)

1  Certificate of Calibration

Installation

Wire Attachment

Attach 18 AWG wires to the unit as described below.  

Strip back the vinyl insulation at each end of the wires 

to approximately 1/3 inch (8 mm).  Twist the stranded 

wire on each end before inserting the wire into each 

connector location.  In order to attach the wire, insert 

a small blade screwdriver into the orange slot above.  

Gently push inward and insert the stripped wire fully 

into the hole in the green connector.  Hold the wire 

fully in and release the screwdriver to allow the wire 

to catch.  Attach the green monitor ground cord to the 

ground connector on back of unit.  Attach the impedance 

monitor wire to the “GND1” connector on the back of the 

unit.