![ScrubbingKing GBZ-430BT Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/scrubbingking/gbz-430bt/gbz-430bt_instruction-manual_1219814015.webp)
15
SQUEEGEE RUBBERS REPLACEMENT
Check the squeegee rubbers wear and replace them if necessary:
1.
Take away the pipe from the squeegee sleeve.
2.
Remove the pins from the column.
3.
Remove the squeegee from its support.
4.
Loosen the wing nuts
①
blocking the rubber blades and take them off.
5.
Replace the rubbers.
6.
Reassemble everything.
COMMON FAULTS AND PROCESSED MEASURES
INSUFFICIENT WATER TO THE BRUSHES
1.
Check the valve lever
①
is open or not.
2.
Check there is water in the solution tank or not.
THE MACHINE DOES NOT CLEAN PROPERLY
1.
Check the brushes wear and replace them if necessary (the brushes must be replaced when the bristles are 15 mm high)
2.
Use another type of brush rather than the standard brush. We recommend, for cleaning exceptionally difficult dirty floors
use special brushes (see “CHOICE AND USE OF BRUSHES)
THE SQUEEGEE DOES NOT DRY PERFECTLY
1.
Check if the squeegee rubbers are clean.
2.
Adjust the squeegee inclination.
3.
Check the connection between the suction pipe and recovery tank.
4.
Remove the whole suction unit and clean it.
5.
Replace the rubbers if worn.
6.
Check if the suction motor switch is turn on.
7.
Check the wheels regulation.