General connections 

   

 

 

12V Trigger 

IR Sensor 

RS485 

Adapter RS232 

+

 = 5 

  30V 

G

 = Ground 

 

NC

 = Not connected 

RS485 

B

 

RS485 

A

 

G

 = Ground 

 
RS485 

=  

-

 RS232 

RS485 

B

 =  

+

 RS232

 

 
Transmission distance: 
1000 meters/3281 feet

 

 

ILT2 motors connections 

  

 

 

SCREEN 

ILT plug M1 

ILT plug M2 

ILT plug M3 

ILT plug M4 

Fixed 4 Way 

Left Mask 

Right Mask 

Top Mask 

Bottom Mask 

Fixed 2 Way lateral 

Left Mask 

Right Mask 

Not connected 

Not connected 

Fixed 2 Way lateral with Deco 

Left Mask 

Right Mask 

Deco Mask 

Not connected 

Fixed 2 Way Top-Bottom 

Not connected 

Not connected 

Top Mask 

Bottom Mask 

Rolling 4 Way 

Projection Fabric 

Top Mask 

Left-Right Mask 

Not connected 

Rolling Top-Bottom 

Projection Fabric 

Top Mask 

Not connected 

Not connected 

Содержание ILT2

Страница 1: ...User and Installation Manual Manual INTERFACES for ILT2 powered screens rev 1 2017 AdeoSreen All Rights Reserved Page 1 ILT2 motorized screens INTERFACE...

Страница 2: ...way or 4 way masked screens There are different versions available In the following table you can compare the various settings based on the version Version Included parts Set or change end limits moto...

Страница 3: ...ren to play with fixed control devices Keep remote controls out of the reach of children Monitor motors when in movement and keep people away from them until they stop TECHNICAL CHARACTERISTICS Power...

Страница 4: ...81 feet ILT2 motors connections SCREEN ILT plug M1 ILT plug M2 ILT plug M3 ILT plug M4 Fixed 4 Way Left Mask Right Mask Top Mask Bottom Mask Fixed 2 Way lateral Left Mask Right Mask Not connected Not...

Страница 5: ...without any operation all motors will react again to any operation MOTOR END LIMITS SETTING 1 Adjust UP end limit A Select the motor B To enter in setting mode press the Prog button of the remote con...

Страница 6: ...anced easy to use and extensible automation tool for MS Windows It can use different input output devices to trigger macros Such as serial COM port of your Computer that on their part control a comput...

Страница 7: ...select the file open in the toolbar 2 search the xml file in your PC 3 select the open in the windows C Set the COM Port parameters 1 select the Plugin Serial Port open in the toolbar 2 open menu with...

Страница 8: ...x00 x00 x00 xFA x06 x53 Reset format 6 6EF3FBFFFFFF000000F90652 x6E xF3 xFB xFF xFF xFF x00 x00 x00 xF9 x06 x52 Reset format 7 6EF3FBFFFFFF000000F80651 x6E xF3 xFB xFF xFF xFF x00 x00 x00 xF8 x06 x51...

Страница 9: ...14 0012 0015 0012 0014 0013 0014 0013 0014 0012 0015 02a3 Alternate Pattern 0000 006b 000b 0017 0015 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014 0013 0014...

Страница 10: ...ADEO SCREEN Sp z o o Ul Boleslawa Krzywoustego 31 59 500 Zlotoryja Polska Europe Tel 48 76 850 53 05 Fax 48 76 850 53 70 Italia Tel 39 0461 248211 Fax 39 0461 243850 Email To contact Technical support...

Отзывы: