SECTION 12. ADA Kit
(cont.)
Please validate all local, municipal, state and federal codes before installation. Below are noted reach
ranges from current building codes.
4.2.6 Side Reach. If the clear floor space allows parallel approach by a person in a wheelchair, the
maximum high side reach allowed shall be 54 inches and the low side reach shall be no less than 9
inches above the floor.
308.2.1 Forward Reach Unobstructed. Where a forward reach is unobstructed, the high forward reach
shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finished
floor or ground.
Children Reach Ranges:
Forward or Side Reach
Ages 3 and 4 Ages 5 through 8
Ages 9 through 12
High (Max)
36 inches
40 inches
44 inches
Low (Max)
20 inches
18 inches
16 inches
Mark the inside of the locker for the clip locations and pre-drill
using a 15/64” drill bit. Drill straight and do not drill at an angle,
walk the drill, or allow it to wobble.
Doing so may result in a loose clip.
If drilled properly the clips will fit snug. Push the clips in snug
and place the shelf on top.