Using the Charge Station HMI
33
SCOTT SAFETY
087-0067 REV A
Automatic Cascade fill may be performed using the HMI. Auto cascade allows
cylinders to be filled from either the compressor or the storage tanks without any
manual intervention, either mechanical or software.
•
Start Filling - Enables the SCBA fill in manual cascade mode. The following
minimum requirements must be meet before fill is started:
– The charge station door lock switch indicates the door is locked.
– If applicable based on model, the cylinder’s minimum RFID tag information is
entered either by RFID or manually.
– Both cylinders have the same pressure rating.
– Both cylinders have unexpired hydro test dates.
•
Stop Filling - Disables the SCBA fill in manual cascade mode.
•
Drain - Disabled. It relates to the compressor.
•
Silence - Manually disables the horn(s) on the compressor.
•
Purge - Disabled. It relates to the compressor.
•
Logout - Exists and returns to the pass code/scan card screen.
•
Alerts - Displays both current and history of alerts. See
.
•
Checklist - Displays the list of associated checks in relation to the charge station
operation.
.
Table 16
Alerts with Override Default Settings - Charge Station
ITEM
MEASUREM
ENT RANGE
ALARM
TIME
DELAY
RANGE
TIME
DELAY
ALARM
WARNING
ALARM
SHUTDOWN
ALARM
STATES
HORN
ALARM
MANUAL
OVERRIDE
OVERR
IDE
MAX.
LIMIT
COOL
DOWN
CYCLE
DP
Monit
or
-10 to -104F
0 to 30Min
10Min
-64F
-55F
Yes
Up to 3
(1Hr)
-10F
2Min
CO
Monit
or
0 to 200ppm
0 to 60Sec
30Secs
4ppm
6ppm
Yes
Up to 3
(1Hr)
20ppm
2Min
Oil
Pressu
re
SW
0 to 60Sec
25Sec
Below
30psi
Below 30psi
Yes
No
No
No
Air
Temp
eratur
e
100 to 600F
0 to 60Sec
15Sec
470F
495F
Yes
Up to 3
(1Hr)
550F
Yes
Crank
case
High
Temp
eratur
e
100 to 600F
0 to 60Sec
15Sec
325F
338F
Yes
Up to 3
(1Hr)
345F
2min
Содержание HushAir Connect 7500
Страница 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Страница 2: ......
Страница 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Страница 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Страница 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Страница 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Страница 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Страница 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Страница 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Страница 119: ......
Страница 120: ...Monroe Corporate Center P O Box 569 Monroe NC 28111 Telephone 800 247 7257 FAX 704 291 8330 Web www scottsafety com ...