56
Model 4688-IR / 4679-IR
Operation & Maintenance Manual
Manual #087-0007G, 10/2003
Maintenance
Maintenance Safety
The GasPlus-IR transmitter should be properly grounded before any
maintenance is performed. Appropriate procedures to declassify the area (if
necessary) should be followed.
Routine Maintenance
Inspecting Dust Filters
Dust filters should be visually checked on a routine basis and replaced, if
necessary. Use past maintenance records and good judgement to determine
when dust filters should be inspected. For example, transmitters located in
dirty or dusty environments should be checked more often than transmitters in
relatively clean areas. Keep a maintenance log for each transmitter and note
the condition of the transmitter when inspected.
First examine the dust shield filters, looking for evidence of clogging or
coating. Then, remove the dust shield cage by gently turning it to the left until
the twist-lock fitting unlocks, then pull downward. Inspect the mirror assembly
filter, again looking for clogging or coating. Replace the dust shield cage,
taking care to align the twist-lock pins with the corresponding slots on the dust
shield cage. Gently turn the dust shield to the right until the twist-lock fitting
locks in place.
Replacing Dust Shield Filters
Remove the dust shield cage by gently turning it to the left until the twist-lock
fitting unlocks, then pull downward. Remove and replace the ring filter and the
disk filter. Replace the dust shield cage, taking care to align the twist-lock
pins with the corresponding slots on the dust shield cage. Gently turn the
dust shield cage to the right until the twist-lock fitting locks in place.
Replacing Mirror Assembly Dust Filters
Remove the dust shield cage by gently turning it to the left until the twist-lock
fitting unlocks, then pull downward. Grasp the base of the heater wire and
gently pull downward to unplug it from the heater wire connection pin.
Do not allow the heater wire connection pin to make contact with
Do not allow the heater wire connection pin to make contact with
Do not allow the heater wire connection pin to make contact with
Do not allow the heater wire connection pin to make contact with
Do not allow the heater wire connection pin to make contact with
foreign metal objects when the instrument is powered, as this will
foreign metal objects when the instrument is powered, as this will
foreign metal objects when the instrument is powered, as this will
foreign metal objects when the instrument is powered, as this will
foreign metal objects when the instrument is powered, as this will
blow the fuses in the protective intrinsic safety barrier and will
blow the fuses in the protective intrinsic safety barrier and will
blow the fuses in the protective intrinsic safety barrier and will
blow the fuses in the protective intrinsic safety barrier and will
blow the fuses in the protective intrinsic safety barrier and will
rrrrrequir
equir
equir
equir
equire r
e r
e r
e r
e replacement of the case fitting assembly
eplacement of the case fitting assembly
eplacement of the case fitting assembly
eplacement of the case fitting assembly
eplacement of the case fitting assembly
.....
Remove and replace the mirror assembly dust filter (part number 077-0166).
Grasp the base of the heater wire and gently plug it into the heater wire
connection pin. Replace the dust shield cage, taking care to align the twist-
lock pins with the corresponding slots on the dust shield cage. Gently turn the
dust shield cage to the right until the twist-lock fitting locks in place.
POWER
SWITCH
Place in the OFF position
before removing Display /
CPU board stack. Ensure
power switch is in
the OFF position prior to
replacing board stack.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com