Scotsman SLD150 Скачать руководство пользователя страница 7

Final Check List/Initial Start Up

1. Check that electrical power has been supplied.

2. Check that a drain, separate from the ice
machine, insulated and made of rigid tubing, has
been connected to the dispenser.

3. Check that the ice machine has been properly
installed per the ice machines installation
directions.

4. Check that the ice machine/dispenser assembly
is level front to back and left to right.

5. Check that optional kits, if any, have been
correctly installed.

6. Check that the sink key, and coin box key if
used, are available.

To Start:

1. Connect electrical power.

2. Go thru ice machine start up procedures. Let ice
machine make two harvests.

3. Push vend switch button in.

4. Rotor should rotate 1/4 turn and stop.

5. Ice will be dispensed from ice chute.

6. Remove sink, and check drain area for leaks. If
none, replace sink.

7. Fill out the warranty registration form and place
it in the mail.

8. Give the operator the key(s) and instructions on
the operation and maintenance of the product.
Check that the operator knows who to call for
service, and has the product/service manuals for
the machines.

Electrical Sequence

Pushing the vend button closes a contact to the
gear motor (and to the ice door solenoid of
SLD150-1B models). 

SLD150-1 model: When the gearmotor begins to
turn, the cam switch on the gearmotor closes, so
that the vend switch may be released without
interrupting the vending, until the cam has moved
1/4 turn. The cam switch then opens to terminate
the vend.

SLD150-1B model: The gearmotor and ice door
solenoid will have power and the dispenser will
continue to operate as long as the dispense switch
is pushed in. This model also has a agitation cycle
of 3 seconds every 2 hours. The solenoid does not
engage during agitation and no ice is dispensed.

SLD150

October 1996

Page 7

Содержание SLD150

Страница 1: ...s the ice up to the top front of the hopper where there is an outlet to the ice chute Table of Contents Specifications Limitations page 2 Installation page 3 Kits page 5 Final Check List Initial Start...

Страница 2: ...SLE300 or SLE400 Slim Line brand models Must allow space for utility connections at the back Must have a drain Optional Kits for SLD150 1B Include Coin Mechanism kit number KSLDC2 Key Mechanism kit nu...

Страница 3: ...el Connect 3 4 rigid tubing to this connection a vent is recommended for most installations Route the drain tubing to the building drain Follow all applicable plumbing codes Because the drain tubing w...

Страница 4: ...slightly Uncoil about 18 of bin thermostat capillary tube Push the end of the capillary tube thru the plastic tube located to the left of the compressor Observe the tube as it pushes down out of the...

Страница 5: ...gram from the kit 15 Reconnect the electrical power supply to the machine 16 Place a container in the drop zone of the dispenser Place a quarter in the slide of the coin mechanism and hold in the safe...

Страница 6: ...l motel key into the cylinder and adjust lever of micro switch so the switch closes when the key is pushed all the way in 10 Install plate and switch assembly into dispenser Secure with nuts removed f...

Страница 7: ...leaks If none replace sink 7 Fill out the warranty registration form and place it in the mail 8 Give the operator the key s and instructions on the operation and maintenance of the product Check that...

Страница 8: ...Operational Schematic Ice Machine Ice Chute Gear Motor Sink Drain Pan Condensate Pan Drain Storage Bin Bin Thermostat SLD150 October 1996 Page 8...

Страница 9: ...F 1150 F water Wash the entire bin area and the delivery area Use a clean brush or cloth 9 Rinse all areas washed with clean fresh water 10 Using the ice machine cleaning solution clean the ice grill...

Страница 10: ...l Gearmotor open Check replace gearmotor Cam switch open SLD150 1 Check replace cam switch Adjust cam switch to close when on high part of cam Ice door does not open SLD150 1B Check for power to solen...

Страница 11: ...earmotor 8 Mark position of cam switch bracket and remove bracket with cam switch from gearmotor 9 Remove 4 nuts securing gearmotor to cabinet 10 Pull gearmotor down and out of cabinet 11 Remove six c...

Отзывы: