Operational Characteristics 1000 lb system
Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Headmaster maintains a minimum discharge
pressure during freeze of:
·
217 PSIG + 25, -15 PSIG
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at
the CP unit’s compressor. Maximum only occurs
during harvest.
Refrigerant Charge
·
272 oz
Compressor Amps
·
Single Phase 8 to 10
·
Three Phase 5 to 7
Batch Weight: 8 lb
Discharge Pressure Cut Out Switch
·
Cuts Out at: 450 PSIG
·
Resets at: 350 PSIG
Prodigy Eclipse
ä
600, 800, 1000
February 2008
Page 49
70/70/50
90/90/70
120/110/100
Freeze
6 to 8 minutes
8 to 10 minutes
16 to 18 minutes
Harvest
1 to 1.5 minutes
1 to .5 minutes
.5 to 1 minutes
70/70/50
90/90/70
120/110/100
Suction at Ice Making Section, end of Freeze
26 to 31 PSIG
27 to 32 PSIG
30 to 35 PSIG
Suction at Ice Making Section, Harvest
85 to 105 PSIG
90 to 110 PSIG
140 to 160 PSIG
Discharge at Condensing Unit: Freeze - 5 minutes in
230 to 250 PSIG
230 to 250 PSIG
345 to 365 PSIG