Control Switches
The EH222 provides front access to two switches
– On and Off. To switch the machine OFF, push
and release the Off button. The machine will shut
off at the end of the next cycle. To shut the
machine off immediately, push and hold the Off
button for 3 seconds.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
The EH222 includes as standard, the Vari-Smart™
adjustable ice level control system.
Control Options
An optional, field installed control that can be
added to this machine is the Smart-Board™
advanced control board and data logger. See the
next page for more information.
Adjustable ice level control
There is an adjustment post and an additional
indicator light to the right of the four indicator lights
mentioned above. The ultrasonic ice level control
allows the user to control the point that the ice
machine will stop making ice before the bin or
dispenser is full. Reasons for this include:
·
Seasonal changes in ice used
·
Planning to sanitize the bin
·
Certain dispenser applications where maximum
ice level is not desired
Use of control
There are several positions the ice level can be set
to, including Off (knob and label indicators lined
up), where it fills the bin until the standard bin
control shuts the machine off.
Rotate the adjustment post to the desired ice level.
The machine will fill up to that level and when it
shuts off the indicator light next to the adjustment
post will be On.
Suggested Adjustment Knob Position for use with
the ABS: first CW position - as shown above.
Note: Ice will build up in the bin or dispenser at an
angle, the distance set will be from the sensor to
the top of the ice. The sensor position is shown in
the cabinet layout diagrams.
The actual distance between the highest point of
the ice may be closer or further away than the
distance set, depending upon the angle of the ice.
Prodigy Eclipse
ä
600, 800, 1000
February 2008
Page 32
Power
Water
On
Status
De-Scale
Off
02-4294-01 Rev. A.
Adjust Ice Level
Lo
wer
Bin
Full
VariSmart Control Area
Normal Setting for
ABS Dispensers
Setting for Maximum