Water and Drain
Left Draining
: Rotate elbow to the other direction.
Connect ¾” PVC to the PVC fitting.
Back Draining:
Rotate elbow to face the back or
connect PVC directly into the ¾” FPT drain fitting.
No external drain vent is required, venting is
internally provided for.
Note: External drain tubing must be supported to
insure that it does not move and kink the internal
rubber tube.
Water Supply
: A 3/8" flare nut on tubing is located
at the top panel, near the refrigeration tubing.
Inside the hardware bag, inside the cabinet, a 3/8"
inch double male flare adapter is supplied. Use the
supplied adapter to make a 3/8" male flare fitting
for the water inlet.
Connect a cold, potable water supply to the 3/8”
water inlet fitting installed above. Use 3/8" OD
copper or other comparable sized tubing for the
water supply.
Note: This is an NSF listed ice machine and
contains provisions for back-flow prevention in its
design. No external back flow preventer is
required.
Drain:
Connect rigid drain tubing to the reservoir
drain fitting on the left side of the cabinet. Route
the drain either out the back, under the unit
(through the notch in the base) to the left side or to
the right side. A vent is built into the unit, so no
external vent is required.
Run the drain tubing to the building drain. Do not
“Tee” into any other drain, including the bin or
dispenser drain.
Prodigy Eclipse
ä
600, 800, 1000
February 2008
Page 22
Back View, Drain Tubing Installed for Right Side Drain