///////////////////////////WARNING/////////////////////////////
Do all wiring with the electrical power
disconnected.
/////////////////////////////////////////////////////////////////////////
To install the KCMR230 fan relay kit when
using (2) NM950R icemakers and one 230
volt, two circuit remote condenser.
See the remote condenser nameplate for
current requirements to determine wire size to
be used for electrical hookup. Refer to wiring
diagram.
All external wiring should conform to the
national, state and local electrical codes.
Usually an electrical permit and services of a
licensed electrician will be required.
1. Mount the control box in a convenient
location.
2. Attach a solid earth ground wire to the
ground screw.
3. Route connecting wires from the first ice
maker junction box
(marked condenser fan) and connect it to the
KCMR230 terminal strip marked: NO. 1 ICE
MACHINE.
4. Route connecting wires from the second
machine junction box
(marked condenser fan) and connect it to the
KCMR230 terminal strip marked: NO. 2 ICE
MACHINE.
5. Route connecting wires from KCMR230
terminal strip marked: TO REMOTE FAN and
connect at the remote condenser junction box.
POSSIBLE LOCATION
FOR KCM230
CONTROL BOX
FOR THE ELECTRICIAN: Fan Relay Kit - 230 volt (-32) only
NM950R
May, 1989
Page 11