Page 33
Page 33
Sanitation
NOTE. Sanitation of the water system is
recommended to be done once a month.
19. Prepare in a plastic container the sanitation
solution as per manufacturer dilution using warm
water (45-50
°
C).
NOTE. Never mix the cleaning with the
sanitising solution.
20. Follow the procedures as per cleaning (from
item 10 to item 13) just shorting the operation of
the water pump to 10 minutes.
21. Place again the evaporator cover and the
unit service panels.
22. At completion of the freezing and harvest
cycle make sure of proper texture and clearness
of the ice cubes and that, they do not have any
acid taste.
ATTENTION. In case the ice cubes are
cloudy-white and have an acid taste, melt
them immediately by pouring on them
some warm water. This to prevent that
somebody could use them.
23. Wipe clean and rinse the inner surfaces of
the storage bin.
REMEMBER.
To prevent the accumulation
of undesirable bacteria it is necessary to
sanitize every week the interior of the storage
bin.
Содержание MCL 1210 A