SERVICE DIAGNOSIS: Condition - No Ice Being Produced

STATUS: 

NOTHING OPERATES

H. Check: The gear motor, if it will not run, the compressor will not run. If no power to it:

Check: The indicator lights on the circuit board, the bin empty light should be ON, the no water light
should be OFF .

1. If the  bin empty and no water lights are off, check the transformer

a. Transformer “load” side should have 12 to 15 volts.  If not, check the “line” side. The line

 

side should have between 208-230 volts.  If the line side has the correct voltage and the 
load side does not, replace the transformer.

2. If the transformer is good, and the bin empty light is OFF, check the ice level sensors.

a. Remove sensors by sliding them sideways out of the ice chute.  Visually inspect them, 
clean if needed.
b. Look through the ice chute “eye” hole for something blocking the ice chute.
c. If the unit still does not run, replace the ice level sensors.
d. If the bin empty light is still OFF, check the circuit board.

1. Unplug “opto trans” and “LED” connectors from the circuit board.
2. Plug “opto trans” and “LED” connectors from the Scotsman Electronic Control

 

Tester Model NM1 into the circuit board.

a. Move the “bin full” switch on the tester to the full position.  The bin full light
 on the tester should be ON, if not, replace the circuit board.
If the bin full light on the tester is ON, move the tester switch to “bin empty”
the light on the tester should go OFF and the bin empty light on the circuit 
board  should go ON.  If not, replace the circuit board. If it does as above, 
and the machine still does not run, replace the ice level sensors. 

3. If the transformer is fine, and the “no water” light is ON, check the water level sensor.

a. Check the water level in the reservoir, restore if low. If the water level is ok:
b. Remove the water level sensor from the reservoir and clean the tip if dirty.
CAUTION:  THE TIP IS MADE OF GLASS
c.  Replace the water level sensor.  If the no water light is still on, check that the 
"water sen" plug is firmly plugged into the circuit board. 
d.  If the no water light is still on, 

1. Unplug the “water sen” connector from the circuit board.
2. Plug “water sen” connector from the Scotsman Electronic Control tester into 
the  circuit board.

a. Move the water switch on the tester to “no water” and the no water light 
on the circuit board should go on.  If not, replace the board.
b. Move the water switch to the “water” position, the no water light should 
go off, if not, replace the circuit board.
c. If after the above, the machine still will not run, replace the water level
sensor.

MORE INFORMATION ON THE TESTER CAN BE FOUND ON THE LAST PAGES OF THE MANUAL.

FM2402

August  1993

Page 21

Содержание FM2402

Страница 1: ...ctronic circuit for monitoring ice and water level a thermostatic expansion valve and R 22 as the refrigerant TABLE OF CONTENTS Installation For the Installer Specifications 2 Storage Bin 4 Location 5...

Страница 2: ...me Basic Electrical 208 230 60 1 same 208 230 60 3 same Ice Type FLAKE same same same Condenser Type Air Water Air Water The normal finish for the ice machine is enamel sandalwood A stainless steel pa...

Страница 3: ...water test and recommendations regarding filters and treatment 2 In most cases the water used to make ice should be filtered or treated depending upon the water There is no one type of water filter th...

Страница 4: ...urn the leg levelers all the way in preparation for leveling later Return the bin to the upright position remove paper covering the bin gasket Note Do not push bin into position but lift it there Push...

Страница 5: ...FOR THE INSTALLER Location ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS DO NOT STACK ANYTHING IN FRONT OF THE MACHINE S FM2402 August 1993 Page 5...

Страница 6: ...r cooled condensers The water pressure to all lines must always be above 20 psig and below 80 psig Drains Air Cooled Models There is one 3 4 FPT drain for both ice making systems at the back of the ca...

Страница 7: ...machine requires a solid chassis to earth ground wire The ice maker should be connected to its own electrical circuit so it would be individually fused Voltage variation must remain within design limi...

Страница 8: ...ate requirements 3 Have all the plumbing connections been made and checked for leaks 4 Has the machine and bin been leveled 5 Is there a minimum of 6 clearance at the back of the machine for proper se...

Страница 9: ...scharged into the drain 5 The unit should soon be making ice if desired the low side pressure of each system may be checked it should be 25 psig or 2 PSIG The suction line temperature at the compresso...

Страница 10: ...the reservoir to make ice out of Will shut the machine off it there is none Ice Discharge Chute Directs the ice produced by the evaporator into the storage bin Ice Level Sensor An electronic eye it se...

Страница 11: ...uilt in time delay to clear the evaporator of ice when the unit turns off and for the liquid line valve Transformer Supplies low voltage to the circuit board Low Pressure Cut Out Switch A manual reset...

Страница 12: ...ere the two seal faces meet Ice Sweep A plastic cap with fingers It revolves with the auger to sweep the ice into the ice chute Breaker Divider Where the ice is compressed and much of the extra water...

Страница 13: ...Shut Down consists of The compressor relay opens The compressor contactor opens The compressor stops The auger motor is run by the circuit board for 2 more minutes clearing out ice in the evaporator...

Страница 14: ...m of each evaporator Reservoir overflow or evaporator condensation is routed to the drain Water cooled models have a separate water circuit for the cooling water it enters the fitting at the rear divi...

Страница 15: ...r evaporators get more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure where it can easily boil off or evaporate As it evaporate...

Страница 16: ...owed DO NOT induce vomiting Give large amounts of water or milk Call Physician immediately In case of external contact flush with water KEEP OUT OF THE REACH OF CHILDREN 7 Prepare the cleaning solutio...

Страница 17: ...o be checked at least two times per year A Check the bearing by removing the ice chute cover unscrewing the ice sweep removing the water shed unscrewing the breaker cover unscrewing the auger stud Ins...

Страница 18: ...locating pins and out of the unit B Remove two screws and unplug the fan motors D Clean the condenser reassemble by placing the fan motor assembly onto the locating pins replacing the mounting screws...

Страница 19: ...off electrical power and water supply 1 To remove the auger remove the front and top panels 2 Remove 3 hex studs holding ice chute cover to ice chute and remove cover 3 Unscrew and remove ice sweep 4...

Страница 20: ...drier evacuate and weigh in the nameplate charge E Check the high pressure cut out if closed go to F if open check 1 The pressure control opens at 400 psig Check the high side pressure reset the contr...

Страница 21: ...full light on the tester should be ON if not replace the circuit board If the bin full light on the tester is ON move the tester switch to bin empty the light on the tester should go OFF and the bin...

Страница 22: ...il is open replace the contactor 3 Check the auger drive motor centrifugal switch If when the drive motor is running contact 4 black wire removed has no power and all of the above switches have been c...

Страница 23: ...ater leaks replace the water seal if found to be leaking 3 Check the low side pressure normal is about 25 psig If low assume a refrigerant leak locate repair and recharge If no leak the TXV may be res...

Страница 24: ...emaker 8 Reverse to reassemble BIN CONTROLS Ice Level Sensors 1 Disconnect electrical power 2 Remove front panel 3 Remove control box cover 4 Locate ice chute at the base of the chute in front of and...

Страница 25: ...o evaporator d Lift up and remove breaker bearing assembly from auger evaporator 6 Service the bearing Check for rust rough spots and damage a The bearing is pressed into the breaker to remove the bea...

Страница 26: ...hreads b Unscrew auger stud from top of auger c Unscrew 4 allen head cap screws holding breaker to evaporator d Lift up remove breaker from evaporator e If the auger is stuck use a slide hammer type p...

Страница 27: ...n against it 3 The part of the water seal that rotates with the auger must also be replaced Remove the old part from the auger and clean the mounting area 4 Place a small bead of food grade silastic s...

Страница 28: ...then weigh in the nameplate charge Check for leaks 8 Install auger breaker breaker bearing assembly and ice discharge chute in reverse order of disassembly See To Reassemble Evaporator and Auger To Re...

Страница 29: ...otor 2 Unscrew the 4 cap screws holding the gearmotor to the base of the machine 3 Remove the gearmotor from the icemaker Bench test the gearmotor check for oil leaks noise and amp draw To Inspect the...

Страница 30: ...om the fan motors 3 Remove two hex head bolts from top end of fan motor assembly see the illustration 4 Lift up and pull out the fan motor assembly 5 Repair as needed 6 To reassemble Place the fan mot...

Страница 31: ...reclaim or recycle refrigerant The method chosen is up to the service company There are various mechanical devices that may be used to recycle refrigerant at the field level however Scotsman requires...

Страница 32: ...the tester into the circuit board 3 Unplug water sen connector from control board 4 Plug water sen connector from Scotsman tester into circuit board Bin Control a Move the bin full switch on the teste...

Отзывы: