background image

ELECTRICAL SEQUENCE

Refer the wiring diagram as needed.
The following description applies to either one of
the two ice making systems. They operate
independently of each other.
If the machine is switched off at the master switch,
but is otherwise ready to go, switching the master
switch to on does the following:

••

The bin empty light on the circuit board goes on

••

There is a 15 second delay

••

If there is enough water in the reservoir, the
circuit board will allow the machine to start up.

Start up consists of:

••

The compressor relay and auger motor relay
become energized, connecting power to the
windings of the auger motor.

••

The auger motor starts, and the centrifugal
switch closes, connecting power to the
compressor contactor coil.

••

The contactor is energized, connecting power
to the compressor, and the compressor starts.

••

As ice goes past the ice level sensors, the bin
empty light will stay on, and  the machine will
continue to run, unless the ice stays between
the sensors for more than 15 seconds (bin full).
At that point, the bin empty light goes out, and
the machine shuts down.

Shut Down consists of:

••

The compressor relay opens.

••

The compressor contactor opens

••

The compressor stops

••

The auger motor is run by the circuit board for 2
more minutes, clearing out ice in the
evaporator, and then

••

The auger motor relay opens, and the auger
motor stops.

If the ice level sensor is clear (bin empty) for more
than 15 seconds, the machine will start up again.
Another purpose of the circuit board is to turn the
machine off if there is not enough water in the
machine.

••

When the water level  in the reservoir falls
below the water level sensor, the machine will
"shut down"

••

When the water refills the reservoir, the
machine will start up again.

Separate from the circuit board:

••

If the high pressure control (cut out switch)
opens,  the machine will stop immediately
(through the relays on the circuit board). It must
be manually reset at the control .

••

If the low pressure control (cut out switch)
opens, the machine will stop immediately
(through the relays on the circuit board). It must
be manually reset at the control.

••

If the spout switch opens,  the machine will stop
immediately (through the relays on the circuit
board). The spout switch must be manually
reset.

••

Each master switch is the manual control for
each system, but it is not a service disconnect.

FM2402

August  1993

Page 13

Содержание FM2402

Страница 1: ...ctronic circuit for monitoring ice and water level a thermostatic expansion valve and R 22 as the refrigerant TABLE OF CONTENTS Installation For the Installer Specifications 2 Storage Bin 4 Location 5...

Страница 2: ...me Basic Electrical 208 230 60 1 same 208 230 60 3 same Ice Type FLAKE same same same Condenser Type Air Water Air Water The normal finish for the ice machine is enamel sandalwood A stainless steel pa...

Страница 3: ...water test and recommendations regarding filters and treatment 2 In most cases the water used to make ice should be filtered or treated depending upon the water There is no one type of water filter th...

Страница 4: ...urn the leg levelers all the way in preparation for leveling later Return the bin to the upright position remove paper covering the bin gasket Note Do not push bin into position but lift it there Push...

Страница 5: ...FOR THE INSTALLER Location ALLOW ROOM FOR AIR CIRCULATION AND SERVICE ACCESS DO NOT STACK ANYTHING IN FRONT OF THE MACHINE S FM2402 August 1993 Page 5...

Страница 6: ...r cooled condensers The water pressure to all lines must always be above 20 psig and below 80 psig Drains Air Cooled Models There is one 3 4 FPT drain for both ice making systems at the back of the ca...

Страница 7: ...machine requires a solid chassis to earth ground wire The ice maker should be connected to its own electrical circuit so it would be individually fused Voltage variation must remain within design limi...

Страница 8: ...ate requirements 3 Have all the plumbing connections been made and checked for leaks 4 Has the machine and bin been leveled 5 Is there a minimum of 6 clearance at the back of the machine for proper se...

Страница 9: ...scharged into the drain 5 The unit should soon be making ice if desired the low side pressure of each system may be checked it should be 25 psig or 2 PSIG The suction line temperature at the compresso...

Страница 10: ...the reservoir to make ice out of Will shut the machine off it there is none Ice Discharge Chute Directs the ice produced by the evaporator into the storage bin Ice Level Sensor An electronic eye it se...

Страница 11: ...uilt in time delay to clear the evaporator of ice when the unit turns off and for the liquid line valve Transformer Supplies low voltage to the circuit board Low Pressure Cut Out Switch A manual reset...

Страница 12: ...ere the two seal faces meet Ice Sweep A plastic cap with fingers It revolves with the auger to sweep the ice into the ice chute Breaker Divider Where the ice is compressed and much of the extra water...

Страница 13: ...Shut Down consists of The compressor relay opens The compressor contactor opens The compressor stops The auger motor is run by the circuit board for 2 more minutes clearing out ice in the evaporator...

Страница 14: ...m of each evaporator Reservoir overflow or evaporator condensation is routed to the drain Water cooled models have a separate water circuit for the cooling water it enters the fitting at the rear divi...

Страница 15: ...r evaporators get more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure where it can easily boil off or evaporate As it evaporate...

Страница 16: ...owed DO NOT induce vomiting Give large amounts of water or milk Call Physician immediately In case of external contact flush with water KEEP OUT OF THE REACH OF CHILDREN 7 Prepare the cleaning solutio...

Страница 17: ...o be checked at least two times per year A Check the bearing by removing the ice chute cover unscrewing the ice sweep removing the water shed unscrewing the breaker cover unscrewing the auger stud Ins...

Страница 18: ...locating pins and out of the unit B Remove two screws and unplug the fan motors D Clean the condenser reassemble by placing the fan motor assembly onto the locating pins replacing the mounting screws...

Страница 19: ...off electrical power and water supply 1 To remove the auger remove the front and top panels 2 Remove 3 hex studs holding ice chute cover to ice chute and remove cover 3 Unscrew and remove ice sweep 4...

Страница 20: ...drier evacuate and weigh in the nameplate charge E Check the high pressure cut out if closed go to F if open check 1 The pressure control opens at 400 psig Check the high side pressure reset the contr...

Страница 21: ...full light on the tester should be ON if not replace the circuit board If the bin full light on the tester is ON move the tester switch to bin empty the light on the tester should go OFF and the bin...

Страница 22: ...il is open replace the contactor 3 Check the auger drive motor centrifugal switch If when the drive motor is running contact 4 black wire removed has no power and all of the above switches have been c...

Страница 23: ...ater leaks replace the water seal if found to be leaking 3 Check the low side pressure normal is about 25 psig If low assume a refrigerant leak locate repair and recharge If no leak the TXV may be res...

Страница 24: ...emaker 8 Reverse to reassemble BIN CONTROLS Ice Level Sensors 1 Disconnect electrical power 2 Remove front panel 3 Remove control box cover 4 Locate ice chute at the base of the chute in front of and...

Страница 25: ...o evaporator d Lift up and remove breaker bearing assembly from auger evaporator 6 Service the bearing Check for rust rough spots and damage a The bearing is pressed into the breaker to remove the bea...

Страница 26: ...hreads b Unscrew auger stud from top of auger c Unscrew 4 allen head cap screws holding breaker to evaporator d Lift up remove breaker from evaporator e If the auger is stuck use a slide hammer type p...

Страница 27: ...n against it 3 The part of the water seal that rotates with the auger must also be replaced Remove the old part from the auger and clean the mounting area 4 Place a small bead of food grade silastic s...

Страница 28: ...then weigh in the nameplate charge Check for leaks 8 Install auger breaker breaker bearing assembly and ice discharge chute in reverse order of disassembly See To Reassemble Evaporator and Auger To Re...

Страница 29: ...otor 2 Unscrew the 4 cap screws holding the gearmotor to the base of the machine 3 Remove the gearmotor from the icemaker Bench test the gearmotor check for oil leaks noise and amp draw To Inspect the...

Страница 30: ...om the fan motors 3 Remove two hex head bolts from top end of fan motor assembly see the illustration 4 Lift up and pull out the fan motor assembly 5 Repair as needed 6 To reassemble Place the fan mot...

Страница 31: ...reclaim or recycle refrigerant The method chosen is up to the service company There are various mechanical devices that may be used to recycle refrigerant at the field level however Scotsman requires...

Страница 32: ...the tester into the circuit board 3 Unplug water sen connector from control board 4 Plug water sen connector from Scotsman tester into circuit board Bin Control a Move the bin full switch on the teste...

Отзывы: