![Scotsman Eclipse CME686 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/scotsman/eclipse-cme686/eclipse-cme686_technical-training-manual_1218780053.webp)
Operation
Operation
-
-
Harvest Control
Harvest Control
•
Controller begins timing harvest
•
Ice falling interrupts the signal from the ice sensor
emitter to the receiver
– The time of that interrupt is recorded by the controller
– The last time the controller receives an interrupt signal
is saved as the cube release time
– Extra time is calculated from the actual cube release
time
Measured Cube Release Time + Calculated Extra Time =
Harvest Time
Содержание Eclipse CME686
Страница 1: ... CME686 CME810 CP686 CP886 CP1086 Eclipse Technical Training Eclipse Technical Training ...
Страница 15: ...Cascading Shield Cascading Shield ...
Страница 16: ...Evaporator Covers Evaporator Covers ...
Страница 17: ...Freezing Compartment Freezing Compartment Water Trough Cascading Shield ...
Страница 18: ...Temperature Sensors Temperature Sensors Water Temp Sensor Liquid Line ...
Страница 22: ...Compressor Package Compressor Package Three models CP686 CP886 CP1086 ...
Страница 55: ...Refrigeration Schematic Refrigeration Schematic Condenser Compressor Package Ice Making Section ...
Страница 56: ...Condensing Unit Condensing Unit CPR Liquid Inlet Valve N O Headmaster Condenser Bypass Valve Rec Compressor ...
Страница 57: ...Ice Making Section Ice Making Section Suction Vapor Liquid Check Valves TXVs Evaporato rs Vapor Inlet Valve ...
Страница 62: ...Maintenance Maintenance Top Cover Lifts Up Notch in Wall for Front Access ...