Page 26
Page 26
Do the operation as per steps 12 and 13 twice so
to be sure no more traces of descaling solution
remains into the sump.
15. With machine in OFF mode pour on the
upper side of the evaporator platen fresh water
with a capfull of sanitizing solution then turn
again the machine in normal operating mode so
to sanitize all the water system for approx. 10
minutes.
NOTE.
Do not mix descaling with sanitizing
solution to avoid the generation of a very
aggressive acid.
16. Switch OFF the machine and flush out the
sanitizing solution from the sump reservoir then
with the switch in "cleaning" position (II), switch it
ON again.
When water starts overflowing through the
drain line, set the switch to "operation" (I)
position. The unit is now ready to resume
normal operation.
17. Place again the evaporator cover and the
unit service panels.
18. At completion of the freezing and harvest
cycle make sure of proper texture and clearness
of the ice cubes and that, they do not have any
acid taste.
ATTENTION. In case the ice cubes are
cloudy-white and have an acid taste, melt
them immediately by pouring on them
some warm water. This to prevent that
somebody could use them.
19. Wipe clean and rinse the inner surfaces of
the storage bin.
REMEMBER.
To prevent the accumulation
of undesirable bacteria it is necessary to
sanitize every week the interior of the storage
bin.