Remove the cover by removing one screw
on the top of the cover.
If installing a remote carbonator, locate it
nearby.
2. Connect the drain line between drain
pan and building drain.
3. Plug electrical supply cord into 115 volt
outlet so ice bank can begin to form. Do
not turn on the carbonator at this time.
4. Fill water bath until water flows out of
overflow tube.
5. Connect water supply line (field
supplied) from the remote carbonator to
the dispenser.
Connect both inlet C02 water lines to CO2
water from the carbonator.
Connect water supply line (field supplied)
from building source to carbonator.
Connect syrup lines to dispenser, and
install disconnect sockets.
6. Connect primary CO2 regulator to CO2
tank. Secure secondary regulators to wall
or other stationary surface.
7. Connect CO2 line between outlet of
primary regulator and inlet of secondary
regulators.
8. Connect CO2 lines between outlets of
secondary regulators and syrup tanks.
INSTALL DISCONNECT SOCKETS
CORD
PLUGS INTO
115 VOLT
WALL
OUTLET.
THIS UNIT
MUST BE
GROUNDED
SINK BOTTOM. SINK
DRAIN MUST BE
CONNECTED TO
BUILDING DRAIN
CONNECT TUBING
FILL WITH WATER
OVERFLOW
TUBE
WHEN ONE
VALVE IS
NOT
CARBONATED
CAP
WITH
GASKET
AND CAP
NUT
CONNECT
TO FRESH
WATER
CO
2
WATER
IN
LOOP
WHEN
NOT
USING
FRESH
WATER
CO
2
WATER IN
Installation
DD40
February, 1988
Page 3