background image

DD40

Adjustments

There is an adjustment for both the water
and the syrup.
Adjustment screws are located under the
valve cover, and behind the solenoid.
1. Facing the valve, the screw on the right
hand side is the syrup adjustment. The

screw on the left hand side is the  water
adjustment.
2. Turn either screw counter clockwise to
increase flow.

Valve service

To remove:
Push release lever up (located under the
cover on the right side of the valve, near
the back) and pull out the valve. There are
ball checks to automatically shut off the
water and syrup.
Pull apart the electical connectors to the
valve, and remove the valve.
To service:

Rubber Seats(ring actuators):

Remove the four screws in the back of the
rear section. This will let the front and rear
section seperate and expose the ring
actuators.
The ring actuators are reversable, and
interchangeable. When either reversing, or
replaceing them, place the rings of the
actuators into the groves and align the

stainless steel lever of the actuator with the

center of the notch in the front section.

Replace the rear section, be sure that the
ring actuators seat in the groves of the
front and rear section.

Flow Controls:

The adjusting screws and springs may be
removed by first removing solenoid and
then the entire top plate. The adjusting
screws and springs are interchangeable.
To remove pistons, remove the entire top
plate, then remove the retaining spring on
the tip of the adjusting screw. The spring
piston should slide off. Pistons are color
coded: 
Water is green
Syrup is red
Diet syrup is grey.

FLOW

CONTROL

ADJUSTER

RING ACTUATOR

PISTON

February, 1988

Page 9

Содержание DD40

Страница 1: ...bank with 6 electric post mix soda valves Table of Contents General Information Page 1 Installation Page 2 Soda Line Schematic Page 4 Optional Kit Installation Page 5 Start Up Page 6 For the Operator Page 7 Adjustments Page 9 Sanitizing Page 10 Service Diagnosis Page 11 Removal and Replacement Page 13 Booth Valve Page 14 Carbonator Service Page 15 Service Parts Lists and Wiring Diagrams are in the...

Страница 2: ...e use of parts and or other components not specifically approved by Scotsman Scotsman reserves the right to make design changes and or improvements at any time Specifications and designs are subject to change without notice MODEL DD40P 6B 1A DD40S 6B 1A DIMENSIONS H X W X D 26 5 X 18 5 X 26 5 SAME ELECTRCIAL 115 60 1 7 AMPS SAME ICE BANK 40 LB SAME COMPRESSOR H P 1 3 SAME RECOVERY 750 F 3 5 HOUR S...

Страница 3: ...alant Dow Corning 731 Scotsman part number 19 0529 01 or the equivalent With the unit located on the counter as desired A Tilt or lift the unit to expose the bottom flanges of the base frame B Apply the sealant to cover the bottom flanges of the base frame C Return the unit to the desired position on the countertop D Add sealant around the base frame and countertop to provide a seal with a radius ...

Страница 4: ...ied from building source to carbonator Connect syrup lines to dispenser and install disconnect sockets 6 Connect primary CO2 regulator to CO2 tank Secure secondary regulators to wall or other stationary surface 7 Connect CO2 line between outlet of primary regulator and inlet of secondary regulators 8 Connect CO2 lines between outlets of secondary regulators and syrup tanks INSTALL DISCONNECT SOCKE...

Страница 5: ...ysrup Tank CO 2 Tank CO 2 Regulator Syrup Reg Diet Reg Carbonator Tank Carbonato re Water CO 2 In Carbonator Pump Water Filter Hand Valve Water Supply Fresh Water Inlet Loop Refrigeration Unit Agitator Motor Carbonated Water Manifold Soda Schematic DD40 February 1988 Page 4 ...

Страница 6: ...fety If local codes require hard wiring follow these steps REMOVE Cord plug from 115 volt outlet Wiring compartment cover from motor Wire nut from power supply wire quick disconnect terminal from motor terminal and ground wire fastener Cord from motor INSTALL Appropriate bushing into conduit hole in motor Permanent wiring to motor through bushing into wiring compartment One conductor to switch cor...

Страница 7: ...CO2 gas pressure from the carbonator once or twice while filling by pulling up on pressure relief valve on the top of the carbonator 10 Actuate each valve until both water and syrup flow 11 Check each valve for proper adjustment Flow rate per valve should be 1 25 oz per second of carbonated water and 25 oz per second syrup for standard valves For a fast flow valve flow rate should be 2 5 oz per se...

Страница 8: ...and should be changed 1 Fully close clockwise CO2 cylinder valve 2 Slowly loosen CO2 regulator assembly coupling nut allowing CO2 pressure to escape then remove regulator assembly from CO2 cylinder 3 Unfasten safety chain and remove empty CO2 cylinder WARNING To avoid personal injury and or property damage always secure CO2 cylinder with a safety chain to prevent it from falling over Should the va...

Страница 9: ...place on the valve Clean the condenser twice per year 1 Disconnect electrical power 2 Remove one screw and the cover 3 Remove condenser filter and clean it with water 4 Inspect condenser fins if light cannot be seen through the fins the condenser needs to be cleaned by either vacuum compressed air or coil cleaner Do Not use a wire brush 5 Replace the filter and the cover 6 Reconnect the electrical...

Страница 10: ...ar section This will let the front and rear section seperate and expose the ring actuators The ring actuators are reversable and interchangeable When either reversing or replaceing them place the rings of the actuators into the groves and align the stainless steel lever of the actuator with the center of the notch in the front section Replace the rear section be sure that the ring actuators seat i...

Страница 11: ...roduct tank Wash sockets in warm potable water connect sockets to tank containing sanitizing solution 2 Open dispensing valve to allow sanitizing solution to push syrup out of product line cooling coil and valve Continue drawing until sanitzing solution has purged all syrup from system and then close valve 3 Allow sanitizing solution to remain in system for ten 10 minutes 4 To remove sanitizing so...

Страница 12: ...rbonated water lever to make carbonator pump cycle on 3 Water oil or dirt in the CO2 supply 3 Remove contaminated CO2 Clean CO2 system lines regulators etc using a mild detergent Install a clean CO2 supply Dispensed product produces foam as it leaves dispensing valve 1 No ice in ice bank 1 Check if overusing if not refrigeration system may have a dirty condenser If the condenser is clean and the a...

Страница 13: ...2 regulator 4 Inoperable dispensing valve 4 Repair dispensing valve 5 Dispensing valve syrup flow regulator not properly adjusted 5 Adjust dispensing valve 6 Dispensing valve syrup tank quick disconnects or syrup lines restricted 6 Sanitize syrup system Only Syrup Dispensed 1 Plain water inlet supply line shutoff valve closed 1 Open plain water inlet supply line shutoff valve 2 Carbonator power co...

Страница 14: ... the junction plug 6 After repair or replacement of the valve reverse to reassemble Refrigeration Chassis 1 The refrigeration section of the DD40 can be removed from the soda lines valves and main body This is useful when taking it to the shop for repair or cleaning A Disconnect electrical power B Remove cover C Unplug refrigeration power from the connection at the right front of the unit D Unplug...

Страница 15: ...UATOR SOLENOID LEAD MICRO SWITCH VALVE COVER RELEASE ACTUATOR QUICK DISCONNECTRELEASE VALVE NIPPLE QUICK DISCONNECT SECTION RETAINING ROD REAR SECTION BODY RING ACTUATOR COVER PLATE BOTTOM SPOUT SPOUT INSERT FRONT BODY SECTION CARB WATER ACTUATOR PISTON DD40 BOOTH VALVE February 1988 Page 14 ...

Страница 16: ...onator may now be removed and replaced including Float Control disconnect wires at the motor and remove three screws from the collar at the top of the carbonator tank pull float control up and out Check Valves unscrew selected valve from tank Carbonator pump no internal service parts remove and replace Carbonator motor no internal service parts remove and replace 6 Reverse steps of removal to reas...

Отзывы: