CS55 INSTALLATION
ELECTRICAL, WATER, AND DRAIN
December, 1987
Page 3
POWER
SUPPLY
WATER SUPPLY
ADAPTOR
(FIELD SUPPLIED)
DRAIN
LEVEL THE UNIT
POWER CORD
SHUT OFF
VALVE
WATER FILTER
(FIELD SUPPLIED)
ELECTRICAL
1. Locate the nameplate on the lower rear
panel and check that the location source
voltage and capacity are correct for this
unit. The unit is equipped with a grounded
plug connection.
Under no circumstances must the ground
post be altered or removed.
Extension cords are not permitted.
Be certain that the icemaker is connected
to its own electrical circuit and is
individually fused. The maximum allowable
voltage variation should not exceed ten
percent of the nameplate rating.
All external wiring should conform to
the National, State, and local electrical
code requirements. Usually an electrical
permit and the services of a licensed
FOR THE PLUMBER
Water supply and drain connections.
1. The recommended water supply line is a
1/4" o.d. copper tube, the water pressure
must have a minimum incoming pressure
of 20 psig.
2. Connect the tubing to the 3/4" hose
coupling thread water inlet fitting at the
back of the icemaker. An optional adaptor
to go from the 3/4" hose coupling thread to
1/4" compression fitting is available from
your dealer under part number 0533238.
Or a similar adaptor can be purchased
from a hardware store.
3. Install a shut off valve in the incoming
water line near the icemaker so that the
water can be shut off for service.
4. Connect a gravity drain line to the drain
connection at the icemaker. A minimum
slope of 1/4" fall per foot of horizontal run
is recommended. Install the drains per the
local codes.
A vent is recommended on the highest
point of the drain tube, and the drain tubing
must be rigid pipe. Do NOT use flexible
tubing.