1.
Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Cover or remove the ice from the storage bin.
4. Remove the cutter grid cover and the cutter grid.
5. Disconnect the remaining two connectors (bin
and evaporator thermistors) from the bottom of the
control housing.
6. Remove the four hex-head screws from the
control housing and lower the housing so that you
can access the components.
NOTE:
The control housing components consist of:
• (1) Electronic control board
• (2) Dual transformer
• (3) Light switch
• (4) Push-button switch assembly
7. To remove the electronic control board:
a) Disconnect the six harness connectors from the
board terminals.
b) Remove the two mounting screws.
Water Pump
Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Remove the ice from the storage bin.
4. Unscrew the drain cap from the reservoir, drain
the water, and replace the cap tightly.
5. Place a cloth in the drain hole to avoid hardware
from falling inside.
6. Remove the hex-head screw from the water
recirculation pump shield and remove the shield
(see the photo below).
July 2007
Page 21
CS0415
Service Manual
Removal and Replacement - Controller
Electrical Shock Hazard
Electrical shock can
cause personal injury.
Disconnect electrical
power before proceeding.
Screw
Water Reservoir
Reservoir
Drain Pump
Drain Cap
Содержание CS0415
Страница 1: ...Service Manual for Cuber Model CS0415 ...