BC0530 User Manual
March 2020
Page 3
This ice maker is designed to be installed indoors,
in a controlled environment. Although it can operate
in a wide range of air and water temperatures, it
will provide the best performance if not subject to
extremes.
Air Temperature Limitations
• Maximum: 90
o
F or 32
o
C
• Minimum: 50
o
F or 10
o
C
Ambient temperatures less than 15°C (60°F)
may cause erratic bin level control operation.
Ambient temperatures higher than the maximum
specification will result in reduced capacities
and high system pressures.
Water Temperature Limitations
• Maximum: 90
o
F or 32
o
C
• Minimum: 45
o
F or 7
o
C
Water Pressure, Potable
• Maximum: 80 PSI or 5.5 BAR
• Minimum: 30 PSI or 2 BAR
Potable Water Inlet Flow Rate
• 2.5 gpm
Voltage 115 volt models
• Maximum 126 VAC
• Minimum 104 VAC
Operating the machine outside of any of the above
limitations is considered abuse and any resulting
damage is not covered by warranty and could cause a
complete loss of warranty coverage.
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage.
In general, warranty covers defects in material
or workmanship. It does not cover maintenance,
corrections to installations, or situations when the
machine is operated in circumstances that exceed the
limitations printed above.
Product Information:
The BC is available in a single cube size. The ice size
cannot be changed significantly. It is a modular cuber
and the ice is stored in separate insulated bin with ice
level automatically maintained by the control system.
A back flow preventer may be required by local
plumbing codes.
Air flow is in the back and out the front and sides.
For available options and kits, see sales literature.
Storage Bins
The ice machine will likely be too deep to fit properly
on a typical ice storage bin. Scotsman B530 bins will
require attachment bracket that is included with the
ice machine.
Dispensers
The BC0530 is NOT COMPATIBLE with any
dispenser. Do not attempt stacking onto a dispenser
or using the ice in a dispenser..
Specifications
Model
Electrical
(Volts/Hz/Phase)
Condenser
Cube
Size
Maximum Fuse
Size or Breaker
(Amps)
Minimum
Circuit
Ampacity
Power Cord
Termination
BC0530A-1A
115/60/1
Air
Large
25
1
9
.6
Not supplied
Always refer to the dataplate for electrical information.
EQUIPMENT CLEARANCE REQUIREMENTS
Clearance must be provided for ventilation and maintenance access. Ventilation is especially important for
models with air cooled condensers. Failure to provide adequate clearance may result in reduced capacities
and high system pressures. The minimum clearances for proper ventilation and access are:
Model
Left Side
Right Side
Rear
Top
BC0530A-1A
4”
4”
4”
1”