Note: Use a clean plastic bottle fitted with a stopper
or cap that has a pouring tube and a vent to facilitate
mixing and pouring of the specified solutions.
1. Mix 3 oz. of Scotsman Clear 1 Scale Remover in
a gallon of warm water.
2. If the ice machine is operating, wait until the ice
falls out of the evaporator, then move the Ice-
Clean Switch to the “Clean” position.
3.
Empty the storage bin and turn off any other ice
machines on the same bin.
4.
After the water fill is complete, turn off the ice
machine.
5. Separate the probe cap from the water level
control tube.
6. Hold the water level control tube upright, so that
it does not overflow.
7. Pour about half of the cleaning solution into the
top of the water level control tube.
8. Return the probes and cap to the water level
control tube.
9. Pour the remaining cleaning solution into the
control stream box.
10. Turn on the ice machine and allow the solution
to circulate for 15 minutes then pull down on the
right side of the water plate. This will cause it to
open and dump the cleaning solution and then
refill with water. Repeat the dump process three
times to be sure all the cleaning solution is rinsed
out of the machine.
11. Mix a sanitizing solution containing 0.5 ounce
(15 ML) 5-1/4% sodium hypochlorite (household
bleach or equivalent) and 1 quart (3.8 Liter) clean
water.
12. Using the same process as in steps #5-8, pour
half of the sanitizing solution into water level
probe tube and the other half into the control
stream box.
13. Allow the solution to circulate for 15 minutes.
Pull down on the right side of the water plate, to
cause it to open and dump the sanitizing solution
and then refill with water. Repeat this process
two times to be sure all the cleaning solution is
rinsed out of the machine. If necessary, adjust
the water level probes to the proper levels.
14. While the cleaning and sanitizing solutions are
circulating, clean and rinse all accessible parts
and surfaces of the ice machine with clean
towels and . Mix a cleaning solution containing
8 tablespoons (1/2 cup) (96g) baking soda and
1 Gal. (3.8 Liter) of warm water and a sanitizing
solution containing 1 teaspoon (5 ML) 5-1/4%
sodium hypochlorite and two quarts (1.9 Liter) of
clean water.
15. After cleaning has been completed, move the
Ice-Clean Switch to the “Ice” position. Check the
operation of the machine, particularly the water
level and subsequent ice cube formation. Adjust
the water level probes if needed.
Cleaning Water System
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner comes
in contact with skin, flush with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.