background image

DataTrack Waiter Call USA Version

 

 

DTKWCUSA 02/00 

 

Issue 1 

5

 

System Overview 

 

The Scope DataTrack Waiter Call is a desktop radio transcoder that can be used to transmit numeric 
and multi-call/pulsed vibrate messages direct to pocket pagers carried by individuals or entire groups.  
The system has 14 individual call buttons that can transmit any of three different call types direct to 
the user’s pager. 

 
 

Options 

 

1)  Desk mount unit with right angle antenna.   

 

Model DTUSAWCD

 

2)  Wall mount unit with bracket kit and straight antenna. 

Model DTUSAWCW

 

3)  Both the above systems can also be ordered with Single Call (

S

) software* 

 
* add 

S

 suffix to part number e.g. 

DTUSAWCDS 

 

 

 

Base Equipment type & description: 

DataTrack Waiter Call, desktop paging transcoder
 

 

Transmitter FCC ID:   

 

 

JRNUSADATALINK 

 
Transmitting Frequency: 

 

 

457.600 MHz or 457.575MHz* 

 
Effective 

Range: 

   

Up to 1 mile with standard aerial

!

 

 
*or as specified on order documentation 

!

optional external aerials and amplifiers available for greater range 

 

 
 

Section 1: Installation 

 

Location of the hardware 
 
 
Desk mounted units 
 

1 Fit the right angle antenna to the BNC connector at the rear of the unit. Twist the collar clockwise 
until it locks into place. Ensure the antenna is in the upright position (see diagram 2, page 7). 
 
2 Fit the power connector into the socket provided at the rear of the unit. Ensure this is pushed in as 
far as it will go. Plug in the AC adaptor to a suitable mains (110V ac) wall outlet. 
 
3 Check the location of the DataTrack unit, observing the recommendations detailed on page 6. 

Содержание DataTrack 20

Страница 1: ...DataTrack 20 Waiter Call Installation and User Manual ...

Страница 2: ...as the standard assigned license You should obtain the FCC Rules and Regulations Title 47 Part 80 to End including Parts 90 and 95 available from the US Gov Printing Office GPO Bookstore FCC Office or www fcc gov oet info rules Important Safety Information Scope products are designed to operate safely when installed and used according to general safety practices The following requirements should b...

Страница 3: ...ired will vary between applications If portable equipment has been dropped or is worn by a person involved in an accident the unit should be tested again before re use It must be stressed that the physical range tests are essential and that any construction work or movement of plant or equipment could alter the signaling capability of the unit Radio equipment like any other requires servicing from...

Страница 4: ...ct indirect special incidental or consequential damages resulting from any defect in the product even if advised of the possibility of such damages The warranties and remedies set forth above are exclusive and in lieu of all others oral or written expressed or implied No Scope distributor dealer agent or employee is authorized to make any modification extension or addition to this warranty Some st...

Страница 5: ...e Equipment type description DataTrack Waiter Call desktop paging transcoder Transmitter FCC ID JRNUSADATALINK Transmitting Frequency 457 600 MHz or 457 575MHz Effective Range Up to 1 mile with standard aerial or as specified on order documentation optional external aerials and amplifiers available for greater range Section 1 Installation Location of the hardware Desk mounted units 1 Fit the right...

Страница 6: ...f the three holes Check that the bracket is vertical prior to fixing Drill and fix the bracket to the wall using suitable wall plugs and fixing screws 4 Offer up the DataTrack unit and slide down onto the bracket checking that the lugs on the bracket fit either side of the lip on the DataTrack base 5 Fit M3 screw to the base of the unit and tighten until the bracket is locked in place 6 Check that...

Страница 7: ...tion check that the Waiter Call keypad unit has it s aerial correctly fitted and that the 12v power lead is firmly plugged into the socket provided at the rear of the unit The red POWER light on the fascia panel will be lit to indicate that the power is connected and the unit is ready for use If the light is not on check that the lead is plugged into the back of the unit and the AC adapter supply ...

Страница 8: ...e button X2 or X3 will cancel the call type When the pager receives the call X2 it will vibrate for a two short bursts and display the message 2 to indicate call type two When the pager receives the call X3 it will vibrate for a three short bursts and display the message 3 to indicate call type three Diagram 2 Desk mounted DataTrack configuration Important Note In the event that you wish to send m...

Страница 9: ...andard Single Call software Operation is the same as the Standard software described above with the following difference For all call types the pager will only vibrate or beep for a single burst The pager will however still show the call type 1 2 or 3 on it s display ...

Страница 10: ...transmit Transmitter Frequency Range 450 470 MHz Channel Spacing 25 KHz or 12 5KHz TX Baud Rate 1200 POCSAG Numeric or Alpha FCC Approval No JRNUSADATALINK General Footprint mm 220 L x 130 W x 90 H max Mounting Desk or Wall mounted with optional bracket excluding aerial Scope s policy is one of continuous development and specifications are subject to change without prior notice ...

Отзывы: