EN
OEM Manual – CUBO
2
AQUA
UMT/WG T MT Rev3.0 – 08/10/2021
Pag. 39-EN
39
18
General information and limits
General Characteristics
Cubo2 AQUA line
UMT/WG T 030 MT DX UMT/WG T 045 MT DX UMT/WG T 067 MT DX UMT/WG T 100 MT DX
models
Refrigerant
R744 (CO2)
Compressor
Toshiba
DY30N1F-10FU
DY45N1F-10FU
DY67L1F-10FU
RY100L1F-10FU
Motor
Rotary Compressor
Number of cylinders
1
1
2
2
Number of poles
4
Moto type
DC Brushless
Revolution range
25 ≈ 100 rps
25 ≈ 100 rps
25 ≈ 100 rps
25 ≈ 100 rps
Oil charged
520 ml
520 ml
450 ml
450 ml
Oil type
PAG VG100
Discharge working
pressure range
125 bar max
125 bar max
125 bar max
125 bar max
Suction working pressure
range
12 ≈ 41 bar
12 ≈ 41 bar
12 ≈ 41 bar
12 ≈ 41 bar
Evaporating temperature
-15 °C ≈ +5 °C
Susction Superheating
10 K ≈ 20 K
Discharge temperature
max 130 °C
Ambient temp.
-15 °C ≈ +43 °C
-20 °C only with winter kit option
Water Inlet temp
+7 °C ≈ +37 °C
System
Receiver
2x 2,4 lt or 1 x 8 lt (/S model)
2x2,4 lt l (The max permitted CO2 charge must guaranty that, in case of pump down at EEV in
front of Evaporators, refrigerant inside the receiver will not exceed 3.5kg)
8 l (The max permitted CO2 charge must guaranty that, in case of pump down at EEV in front of
Evaporators, refrigerant inside the receiver will not exceed 7.2kg)
Suction line
3/8" K65 (9,52mm)
3/8" K65 (9,52mm)
3/8" K65 (9,52mm)
1/2" K65 (12,70mm)
Liquid line
3/8" K65 (9,52mm)
3/8" K65 (9,52mm)
3/8" K65 (9,52mm)
3/8" K65 (9,52mm)
PS Suction / Liquid
80 bar / 80 bar
PED Category
PED Category I for model with 2x2,4 lt Liquid Receiver
PED Category II for model with 1x8 lt Liquid Receiver (/S)
Dimensions (AxBxH)
1150 x 570 x 805 mm
Generic
Trasport dimensions
(AxBxH)
1300 x 700 x 950 mm
Weight
150 Kg
Transport way
Pallet & Carton
Painted
RAL 7035
Sound level (max speed)
1)
41 dBA
41 dBA
41 dBA
41 dBA
1)
Sound pressure and sound power analytically calculated. Sound pressure level at 10 m in free field.
19
Electrical details
Electrical Information
Cubo2AQUA line Size UMT/WG T 030 MT DX UMT/WG T 045 MT DX UMT/WG T 067 MT DX UMT/WG T 100 MT DX
Power Suply
230V/1Ph+N+PE/50Hz
400V/3Ph+N+PE/50Hz
Recommended protection
Circuit Breaker
Circuit Breaker
Circuit Breaker
Circuit Breaker
C16A
C16A
C25A
C20A
MRA
9,4 A
13,9 A
20,9 A
15,1 A
P abs max
2115 W
3155 W
4765 W
7560 W
MRA = Maximjum Rated Abs.
Unit is made in accordance with EN-60204-1. All electrical cabling, in external unit, have been
made in accordance with EN-60204-1.