INCU-C Series V2018.1.1 

10 

 

Actual Temperature Indicator: 

 

LCD displays the value of actual temperature 
 
 

Graphic Temperature Indicator:  

LCD displays the graphic chart of the set temperature and actual temperature 
 

Time indicator:  

When the LCD displays the operating time

, t

his indicator will light, it twinkles when the 

screen displays  
the preset time. 
 

Operating status indicator:  

When the unit operates as normal, this indicator will light up. 
 

Status hold

 

indicator:

 

Indicator of 

“Hold” step in program control mode. this indicator will light, if the program is 

entering "hold" step, in another word, the "Hold time" starts counting down. 
 

Refrigeration indicator: 

 Lights 

“ON” when solenoid valve is “Open” to cool down the incubator 

 
 

PV 

SV 

TM 

RUN 

COLD 

HOLD 

Содержание INCU-160C

Страница 1: ...User s Manual This Manual applies to Models INCU 90C INCU 160C INCU 270C INCU 430C INCU C series Economic Cooled BOD Incubator...

Страница 2: ...dustries such as medical pharmaceutical and agricultural It is widely used for breeding fermentation micro organism cultivation constant temperature environmental test denaturation experiments and the...

Страница 3: ...In case of malfunction or burning smell the unit must be unplugged immediately Use a circuit breaker to cut off the power supply Continuance of abnormal state will end up with fire as a result of ove...

Страница 4: ...peration do not open the door too much or too long as this might affect the temperature inside 9 The incubator must be kept away from volatile flammable explosive liquids or gases 10 Please keep the c...

Страница 5: ...ration and Start up 11 5 Setting of the Control Mode 12 6 Setting Parameters for Constant Temperature Control Mode 13 7 Setting Parameters for Programmable Control Mode 15 8 Settings of the Other Func...

Страница 6: ...nd cool down the incubator to the required temperature The 3 dimensional air circulation motor fan speed adjustable in three steps via the con troller ensures optimum temperature distribution across t...

Страница 7: ...igital Display LCD Grids Included 2 Max 11 2 Max 15 2 Max 18 2 Max 25 Grid Size mm WxD 310x356 410x456 513x556 555x656 Inner Dimensions mm WxDxH 400x410x550 500x500x650 600x600x750 700x645x950 Exterio...

Страница 8: ...INCU C Series V2018 1 1 8 3 Control Panel Illustration of Control panel...

Страница 9: ...g button Under fixed value mode press the button to start the unit Press the button again to stop In the Programmable mode press the button to start running the unit Press it again to enter the Hold s...

Страница 10: ...this indicator will light it twinkles when the screen displays the preset time Operating status indicator When the unit operates as normal this indicator will light up Status hold indicator Indicator...

Страница 11: ...wer is applied to the unit and the LCD displays the following in turn Time Function Preset Temperature Measured Temperature Clean the chamber of incubator before you put it into use and on a regular b...

Страница 12: ...ired control mode Stop current operation by pressing the Operation button R H S Press the SET key and enter the password 1 Press the SET key again until the LCD display shows the control mode options...

Страница 13: ...et function Press the Increase or Decrease key to set the de sired temperature 6 2Set Timer Only if you want to run the incubator on the Timer otherwise just leave it as 0 To set timer press the Set k...

Страница 14: ...heating up temperature control mode model INCU 160C INCU 270C for time and temperature at an ambient of about 25 C This will help you to set the parameters in the Programme mode chapter 7 Other model...

Страница 15: ...gment 1 Use the decrease and or increase buttons 7 8 Press SET to store and enter the next segment S2 setting process 7 9 Press increase or decrease button to enter the second Ramp Time S2 And so on 7...

Страница 16: ...wing segments 10 in total Special attention To pause the current program press R H S key and press again to resume To abort the program any time press the R H S key for 3 seconds To continue press the...

Страница 17: ...n to enter into time set menu Press Increase or Decrease key to set the right time of day Press the SET key again the display shows the year press the Increase or Decrease button to change it to the a...

Страница 18: ...240 hours Set it as 0 to disable the auto defrosting function Once the defrost timer is set the unit will automatically perform the defrosting cycle accordingly To find out the suitable defrost timer...

Страница 19: ...aph Press the SET key to enter the password 8 Press the Set key again to enter rec ord time function Press the Increase or Decrease key to modify the interval time for chart display Press the Set key...

Страница 20: ...ed the chamber is fully loaded and forced air circulation is required this unit is installed with main ventilating fan speed adjusting option to provide further flexibility for various applications Th...

Страница 21: ...R H S button once more and the unit will start again to count down from the preset operation time 9 4 While the unit is in use the current remaining operating time cannot be changed If however changed...

Страница 22: ...reading is 6 C difference would be 6 8 2 C while if reading is 9 C the difference would be 9 8 1 C 11 4 Press the SET button and go with the up arrow to code 47 11 5 Press the SET again to enter the S...

Страница 23: ...mperature Point Correction 100 0 11 9 If the incubator is to be used for more than one temperature setting and High Temperature Point Correction 100 0 needs to be performed as well 11 10 Change the se...

Страница 24: ...ter is wrong Refer to the operating procedure and change or re set alarm parameter 3 Malfunction of heating system Notify your distributor for repair Real temperature PV is lower than the set SV tempe...

Отзывы: