background image

 

 

7” Square Hotplate

 

6.

 

Working 

with 

external 

temperature sensor

 

 

Figure 6 

The  external  temperature  sensor  PT1000  is  the 

Manufacture’s standard  accessory.  If  the sensor is plugged 

in  and  rotate  the  heating  knob,  LED  displays  the 

temperature  setting  value  and  shifts  to  real  value  in  5 

seconds.  Safe  circuit  controls  hotplate  temperature. 

Comparing with the temperature control of the hotplate, the 

external  temperature  sensor  can  control  the  medium’s 

temperature  more  precisely.  The  heating  function  will  be 

stopped  automatically  under  abnormal  conditions.  Please 

operate follow the instructions below: 

 

Switch OFF the instrument. 

 

Ensure  the  external  temperature  sensors  is  inserted  in 

the media heated.   

 

Switch ON the instrument and run heating function. 

If  the  heating  function  did  not  work,  please  contact 

manufacturer/supplier for technical support.   

7.

 

Residual heat warning 

In order to prevent the risk of burns from a hotplate, digital 

hotplate  has  a  residual  heat  warning  function.  When  the 

heating  function  is  switched  off  and  the  heating  plate 
temperature  is  still  above  50°C,  “Hot”  will  flash  to  warn 

that there is a hazard of burns from the hotplate. When the 

hotplate  temperature  drops  to  below  50°C,  the  unit  will 

automatically switch off. If users want to turn off the LCD 

or  LED  immediately,  just  pull  out  the  plug  directly.  When 

the  plug  is  pulled  out,  the  residual  heat  warning  function 

cannot be run.

 

Содержание HP550-S

Страница 1: ...LED Digital 7 Square Hotplate Please read the User Manual carefully before use and follow all operating and safety instructions We cannot be responsible to inform at real time if the outline and speci...

Страница 2: ...ving Inspection 3 3 2 Listing of Items 3 4 Control 4 4 1 Control elements 4 4 2 Display 5 5 Trial run 5 6 Working with external temperature sensor 6 7 Residual heat warning 6 8 Faults 7 9 Maintenance...

Страница 3: ...or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use...

Страница 4: ...he media used Be aware of hazards due to unsafe container Process pathogenic materials only in closed vessels Check the instrument and accessories prior to each use Do not use damaged components Safe...

Страница 5: ...uitable for using in residential areas or other constraints mentioned in Chapter 1 3 Inspection 3 1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen...

Страница 6: ...ns Temperature control knob The heating function is switched ON or OFF by rotating knob LED Display If rotate the heating knob LED displays the temperature setting value and shift to real value in the...

Страница 7: ...Hot otherwise LED displays 0 5 Trial run Make sure the required operating voltage and power supply voltage match Ensure the socket must be properly grounded Plug in the power cable ensure the power i...

Страница 8: ...itch OFF the instrument Ensure the external temperature sensors is inserted in the media heated Switch ON the instrument and run heating function If the heating function did not work please contact ma...

Страница 9: ...g tenside Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Wear the proper protective gloves during cleaning of...

Страница 10: ...equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pro...

Страница 11: ...ent 5 Temperature display C LED Temperature display accuracy C 1 Control accuracy of heating temperature C 10 The safety temperature of the hotplate 580 Temperature sensor in medium PT1000 Control acc...

Страница 12: ...lug 200 240V 50Hz 60Hz 51212122xxxx HP550 S LED Digital 7 Square Hotplate glass ceramics hotplate Euro plug 200 240V 50Hz 60Hz 51212132xxxx HP550 S LED Digital 7 Square Hotplate glass ceramics hotplat...

Страница 13: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com...

Отзывы: