background image

 

 

7” Square Hotplate

 

1.

 

Safety Instructions 

 

Warning! 

 

Read  the  operating  instructions  carefully 

before use. 

 

Ensure that only trained staff works with the 

instrument. 

 

Risk of burn!   

 

Caution  when  touch  the  housing  parts  and 

the  hotplate  which  can  reach  temperature  of 

550°C.   

 

Pay  attention  to  the  residual  heat  after 

switching off. 

 

 

Protective ground contact

 

 

Make  sure  that  socket  must  be  grounded 

(protective ground contact) before use.   

• When working wear personal safety guards to avoid the 

risk from: 

- Release of toxic or combustible gases 

• Set up the instrument in a spacious are on a stable, clean, 

non-slip,  dry  and  fireproof  surface.  Do  not  operate  the 

instrument  in  explosive  atmospheres,  with  hazardous 

substances or under water. 
•  Temperature  must  always  be  set  to  at  least  50

  lower 

than the fire point of the media used. 

• Be aware of hazards due to unsafe container. 
• Process pathogenic materials only in closed vessels. 
•  Check  the  instrument  and  accessories  prior  to  each  use. 

Do  not  use  damaged  components.  Safe  operation  is  only 

guaranteed  with  the  accessories  described  in  the 
“Accessories”  chapter.  Accessories  must  be  securely 

attached to the device and can not come off by themselves. 

Always disconnect the plug before fitting accessories. 

•  When  the  external  temperature  sensor  needed,  the  tip  of 

the measuring sensor must be at least 5-10mm from vessel 

bottom and wall. 
•  The  instrument  can  only  be  disconnected  from  the  main 

power supply by pulling out the main or the connector plug. 
•  The  voltage  stated  on  the  label  must  correspond  to  the 

main power supply. 
•  Ensure  that  the  main  power  supply  cable  does  not  touch 

the hotplate. Do not cover the device. 
• Forbid to put pressure and over heat media on the surface 

of glass ceramic, that can be caused surface broken. 
• The instrument may only be opened by experts. 

Содержание HP550-S

Страница 1: ...LED Digital 7 Square Hotplate Please read the User Manual carefully before use and follow all operating and safety instructions We cannot be responsible to inform at real time if the outline and speci...

Страница 2: ...ving Inspection 3 3 2 Listing of Items 3 4 Control 4 4 1 Control elements 4 4 2 Display 5 5 Trial run 5 6 Working with external temperature sensor 6 7 Residual heat warning 6 8 Faults 7 9 Maintenance...

Страница 3: ...or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use...

Страница 4: ...he media used Be aware of hazards due to unsafe container Process pathogenic materials only in closed vessels Check the instrument and accessories prior to each use Do not use damaged components Safe...

Страница 5: ...uitable for using in residential areas or other constraints mentioned in Chapter 1 3 Inspection 3 1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen...

Страница 6: ...ns Temperature control knob The heating function is switched ON or OFF by rotating knob LED Display If rotate the heating knob LED displays the temperature setting value and shift to real value in the...

Страница 7: ...Hot otherwise LED displays 0 5 Trial run Make sure the required operating voltage and power supply voltage match Ensure the socket must be properly grounded Plug in the power cable ensure the power i...

Страница 8: ...itch OFF the instrument Ensure the external temperature sensors is inserted in the media heated Switch ON the instrument and run heating function If the heating function did not work please contact ma...

Страница 9: ...g tenside Isopropyl alcohol Cosmetics Water containing tenside Isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Wear the proper protective gloves during cleaning of...

Страница 10: ...equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pro...

Страница 11: ...ent 5 Temperature display C LED Temperature display accuracy C 1 Control accuracy of heating temperature C 10 The safety temperature of the hotplate 580 Temperature sensor in medium PT1000 Control acc...

Страница 12: ...lug 200 240V 50Hz 60Hz 51212122xxxx HP550 S LED Digital 7 Square Hotplate glass ceramics hotplate Euro plug 200 240V 50Hz 60Hz 51212132xxxx HP550 S LED Digital 7 Square Hotplate glass ceramics hotplat...

Страница 13: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com...

Отзывы: