Thanks  for  purchasing  Scigiene’s  Mycotoxin  LFD  Incubator.  This  manual  includes  device 

function and operation procedure. Please read the manual before operation. Please check 

device components once you receive goods and contact us immediately if you found any 

parts mismatched, missing or damaged. 

 

1 Introduction  

Incubator is new product controlled by microcomputer. It is widely used for sample preservation and reaction, 

DNA-PCR,  electrophoretic  pre-degeneration,  serum  coagulation  and  etc.  Please  read  the  manual  before 

operation.   
 

1.1 Components  

           

Mainframe                                                                                            1pcs 

          Transparency Cover                                                                              1pcs 
          Power Adapter                                                                                      1pcs 
          Operation Manual                                                                                1pcs 

 

Содержание Mycotox CUSFY-1

Страница 1: ...1 Operation Manual for Mycotoxin LFD Incubator CUSFY 1...

Страница 2: ...stallation 5 2 Technical Parameter 6 3 Safety Warning 6 4 Operation Procedure 7 4 1 Set up a new Procedure 7 4 2 Set S N of Procedure 7 4 3 Set Temperature 7 4 4 Set Time 7 4 5 Set Time Unit 8 4 6 Pro...

Страница 3: ...oods and contact us immediately if you found any parts mismatched missing or damaged 1 Introduction Incubator is new product controlled by microcomputer It is widely used for sample preservation and r...

Страница 4: ...4 1 2 Primary Structure Metal Module Display Operation Panel Power Switch Power Input Socket...

Страница 5: ...r input socket then connect the other end of power adapter with power grid between 100V and 240V Check below chart 1 3 3 Power switch on and then it will reach to setting temperature Basically it take...

Страница 6: ...y 0 1 Heating up Time from 40 to 100 20min Environment Temperature 5 35 Overall Dimension W D H 110mm 148mm 120mm Net Weight 0 5 kg 3 Safety Warning It is used indoor It might cause personal injury if...

Страница 7: ...em comes to operation interface Press Start Stop key over 2 minutes then is goes into Setting up Procedure interface You can DIY 9 procedures P1 to P9 Each procedure includes 3 sections move A B C 28...

Страница 8: ...o A Stop key 4 6 6 It will send warning tone at one minute at a time and also display FINISHED after running complete procedure Meanwhile it will remain at current temperature Please turn off the powe...

Страница 9: ...will exit current menu without saving configuration information 4 7 2 Automatic recovery after power failure ORF Enable ORF it will get back to the procedure run before power failure once when power o...

Страница 10: ...ntact us Module did not heat up Heater malfunction Contact us Key malfunction Broken membrane switch Contact us Regularly clean longhole on module with clean soft cloth that takes a little absolute al...

Отзывы: