Push button for Switching ON/OFF the 230 V mains supply to the

instrument.

(Variable Potentiometer) Variable potentiometer for the coarse

setting of the output voltages from the output terminals. Adjustment range

0

30 V.

(Variable Potentiometer) Variable potentiometer for the fine setting

of the output voltage at terminals. Adjustment range 2.1 V.

(Variable Potentiometer) Variable potentiometer for current limit

setting of the voltage source. Adjustment range

0.1 A - 3.00 A.

Output terminals for DC Power Supply

A

&

B

, 4 mm

banana plugs for connections. The Output is short circuit protected.

Dual display for voltage & current, displays the

values for both supplies A & B . When supply

A

is used in constant

current mode the

A

LED lits ,which shows that the supply A is in constant

current mode. Similarly LED

B

will lit ,

B

is in constant current mode .

When the TRACK mode is selected TK LED will lit.

The instrument is provided with over voltage protection from mains

variation. The mains input voltage is selected by switch on back side. The over

voltage setting is set at 253 V for mains input voltage 230 V & 273 V for mains input

voltage 240 V. Whenever, the mains increases beyond the set voltage, it trips &

LED

HV

is lit. After the mains normalized, switch OFF once the instrument & then

switch ON again, if the mains is below 253 V / 273 V , the instrument get switched

ON , other wise trips again.

&

COARSE

:

F

:

:

Output Terminals :

Display Window :

NOTE :

IMAX

TRACK :

When TRACK push button is pressed and the -ve terminal of A is

connected to +ve terminal of B by a shorting clamp, the power supply is

converted into tracking mode . The supply A act as a Master unit & B as

Slave unit.

2

9

3

8

4

7

5

10

1

1

7

User Manual PSD3205

1

Содержание PSD3205

Страница 1: ...User Manual Dual Display Tracking Multiple Power Supply 3205 PSD...

Страница 2: ...nstrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding p...

Страница 3: ...tions 5 3 Front Panel ontrols 4 Operating Instructions 8 General Information 8 Safety 8 Operating Conditions 8 First Time Operation 9 Operation 9 6 Maintenance 12 Power Line Fuse Replacement 12 7 Disp...

Страница 4: ...as a constant current CC and constant voltage CV source for laboratories industries field testing applications featuring low power loss compact and light weight It provides isolated floated adjustabl...

Страница 5: ...0 30 V 3A B 0 30 V 3A 0 30 V continuously variable by means of coarse fine controls 3 A Max Voltage 10 mV Current 5 mA 10 m 2 5 mV at 30 V 3A 50 s 0 05 10 mV 0 05 10 mV 0 05 5mV C 1 mVrms 1 Adjustabl...

Страница 6: ...1 Front Panel Controls 6 User Manual PSD3205 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF 3 00 A V TRACK 1 2 3 4 5 6 7 8 9 11 10 A 30V 3A B 30V 3A TRACK DUAL DISPLAY TRACKING POWER SUPPL...

Страница 7: ...hat the supplyAis in constant current mode Similarly LED B will lit B is in constant current mode When theTRACK mode is selectedTK LED will lit The instrument is provided with over voltage protection...

Страница 8: ...tion must not be negated by the use of an extension cord without a protective conductor When removing the metal case or replacing the instrument must be completely disconnected from the mains supply I...

Страница 9: ...ns supply 230 V 10 On switch ON no undue observation should be noticed Once the instrument is switched ON the power ON is indicated by liting of displays The power supply has an electrically floating...

Страница 10: ...h shorting clamps connections are done as per above diagram In this mode t he supplyAact as a Master unit B as Slave unit Circuit under Test 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF...

Страница 11: ...eeds 240 V AC it is recommended to select 240 V tapping The over voltage setting for safe operation is set at approx 270 V for mains input voltage when the tapping is set to 240 V Whenever the mains i...

Страница 12: ...aning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instrument does...

Страница 13: ...l details of the fault noticed 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is p...

Страница 14: ...any defect failure or damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LED fuses batteries or accesso...

Страница 15: ...15 User Manual PSD3205 Notes...

Страница 16: ...chennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia...

Отзывы: