WARNING

Burn Hazard

.

Do not touch hot�liquid or heating surfaces

while equipment is heating or operating

Hot surfaces and liquid can burn skin. �llow the hot surfaces to cool 

before handling

CLEANING 

BEFORE CLE�NING THE UNIT� DISCONNECT THE PO�ER PLUG FROM 

THE M�INS SOCKET!

•    Clean the unit using a damp cloth with soapy water. 

•    Do not submerse in water or subject the unit to water spray.

•  The circulator is designed for continuous operation. Periodic  

     maintenance is not required.

•  The tank should only be filled with recommended liquids. To prevent 

contamination it is necessary to change liquid periodically.

•  To maintain the full cooling performance� occasionally clean the 

      condenser by removing the front panel via the two screws and clean 

      the ribbed condenser with a vacuum cleaner. 

CLE�N THE ST�INLESS STEEL P�RTS �ITH ��TER 

�ND SO�P. �VOID THE USE OF DETERGENTS 

CONT�INING �BR�SIVE SUBST�NCES. �L��YS 

RINSE �ELL �ND DRY C�REFULLY �FTER 

CLE�NING. DO NOT USE PRODUCTS CONT�INING 

�GGRESSIVE CHEMIC�LS� �CIDS OR PRODUCTS 

�ITH CHLORINE TO CLE�N THE ST�INLESS STEEL 

EVEN IF DILUTED

EXPLODED DIAGRAM 

COOLING BATH
MODEL: 170

10LT COOLING CIRCULATING BATH MODEL CODE:170 ROO

1

2

3

4

40

39

38

26

25

24

24

23

22

27

21

16

18

19

20

28

32

31

29

30

34

35

37

36

5

6

12

7

8

9

10

11

14

15

17

33

13

4

11

Содержание 170

Страница 1: ...RECEIVE YOUR FULL TWO YEAR WARRANTY MANUFACTURED IN SOUTH AFRICA www scientific co za All Scientific equipment comes with a standard ONE year warranty The 1 Year Extended Warranty is only valid for customers who have registered their warranty online at www scientific co za within the first year after making their purchase WARRANTY ...

Страница 2: ...roduct Code see box label Serial number see back of machine ONLY COMPLETE IF YOU DO NOT HAVE WEB ACCESS INTENDED USE Agriculture Automotive Biochemistry Botony Chemistry Cosmetics Electronics Food Genetics Industrial Medical Microbiology Mining Nuclear Paper Packaging Petrochemical Pharmaceutical Physics Power Generation Special Metals Sugar Water Zoology Other Specify ALL SCIENTIFIC EQUIPMENT COM...

Страница 3: ... All other Warranties expressed or implied statutory or other wise including without limitations any implied Warranty of Merchant ability or fitness for purpose are excluded The Seller shall in no event be liable for direct indirect or consequential damages in connection with the products This unit is at all times to be used according to the instruction manual and for its normal purpose This Warra...

Страница 4: ... for any damage incurred during transit This should be reported to the responsible carrier railway or postal authority and a request for a damage report should be made Part No 1 H NDLE 2 LID COVER 3 LID COVER STIFFENER 4 B SE TOP COVER 5 COOLING COIL 6 B SE 7 MOTOR GRID 8 F N MOTOR 9 IMPELLER 10 CONDENSER 11 FRONT COVER 12 OUTER ENCLOSURE 13 C STORS 14 DRYER 15 COMPRESSOR 16 PO ER CORD PLUG 17 SOC...

Страница 5: ...interior of the circulator when filling Recommended maximum filling level 25mm below the tank rim 2 To drain turn off the circulator and cooling machine Open the ball valve at the rear of unit and drain into a suitable receptacle Temperature application to external systems 1 The circulator is used for temperature applications to external closed systems temperature loop with simultaneous internal b...

Страница 6: ...R00 OPERATING INSTRUCTIONS OF ELECTRONIC TEMPERATURE CONTROLLER 1 The temperature controller has four buttons on the front face These are used to set the required temperature initiate Auto Tuning and enter any adjustments to the program 2 To set the required temperature ensure that the unit is con nected and switched ON in the appropriate manner 3 The top display red shows the actual temperature P...

Страница 7: ...liquids To prevent contamination it is necessary to change liquid periodically To maintain the full cooling performance occasionally clean the condenser by removing the front panel via the two screws and clean the ribbed condenser with a vacuum cleaner CLEAN THE STAINLESS STEEL PARTS WITH WATER AND SOAP AVOID THE USE OF DETERGENTS CONTAINING ABRASIVE SUBSTANCES ALWAYS RINSE WELL AND DRY CAREFULLY ...

Страница 8: ... position 8 Do not operate if equipment has been damaged or is malfunc tioning in any way 9 These units are designed to run only on alternating current A C DO NOT CONNECT TO DIRECT CURRENT D C WARNING Electric Shock Hazard Keep water and other liquids from entering the inside of the equipment Liquid inside the equipment could cause an electrical shock Do not spray water or cleaning products Liquid...

Страница 9: ...or material defects Insulate the tube to prevent excess condensation 6 When you have finished the application it is recommended to keep on circulating the liquid in the bath or system for some time Simultaneously set the working temperature to 20 C to allow the temperature in the system to decrease slowly In this way fractional over heating of the bath liquid is prevented SAFETY RECOMMENDATIONS LE...

Страница 10: ...AR OF THE UNIT ADJACENT TO THE INCOMING CABLE ENTRY ELECTRICAL CONNECTION INFORMATION THE CONTROL COMPARTMENT OF THIS UNIT CON TAINS DANGEROUS VOLTAGES MAINTENANCE AND SERVICING REQUIRING THE REMOVAL OF ANY PAN ELS OR COVERS SHOULD BE DONE BY QUALIFIED SERVICE PERSONNEL ONLY MODEL DESCRIPTION VOLTS V Hz POWER WATTS CAPACITY Lt OPENING SIZE mm 170 LOW TEMPERATURE CIRCULATING BATH 230 50 1000 10 150...