4XLFN6HWXSLQVWUXFWLRQV
Follow these quick setup instructions to set up the receiver via the menu interface
using front panel buttons, and to find a signal using the built-in signal search
function. To operate the menu interface, a RF cable must be connected from the
receiver VIDEO output to a TV monitor UHF/VHF RF input (see Figure A).
Step 1. Power ON the receiver by pressing the STANDBY button.
Step 2. Display the MAIN MENU by pressing the MENU button.
Step 3. Display the RECEIVER STATUS menu by pressing 2 and then SELECT, or
move to Receiver Status and press SELECT.
Step 4. Display the RECEIVER SETUP menu by pressing 3 and then SELECT, or
move to Receiver Setup and press SELECT.
Step 4. Change the Local Oscillator #1 frequency:
(a) Move to L.O. Freq #1 and press SELECT to unlock the current setting
(b) Enter the L.O. #1 Frequency (in GHz) based on C or Ku-Band LNB operation
and press SELECT (e.g., 10750 for Ku-Band, and 5150 for C-Band).
Step 5. Change the Symbol Rate:
(a) Move to Symbol Rate and press SELECT to unlock the current setting
(b) Enter the Symbol Rate (in MS/s) and press SELECT.
Step 6. Change the FEC Rate: by moving to FEC Rate and pressing SELECT to dis-
play available FEC Rates.
Step 7. Activate the signal search to Find the signal (use only if the operating
frequency is unknown) by moving to Find and pressing SELECT (set to ON).
The Lock, Sig Signal State is displayed when a signal is found.
Step 8. Save the settings: (after signal found)
(a) Press 1 and then SELECT, or move to Exit and press SELECT to display the
Save pop-up menu.
(b) Press 1 to save the new configuration (YES).
When the signal is found, the Find option is automatically set to OFF. Repeat this
action to search for another signal. You can perform these functions using the fol-
lowing front panel buttons.
Save: Press and hold down both the Í and Î arrow buttons simultaneously (5) to
save the new configuration (YES)
Discard: Press and hold down both the Ï and Ð arrow buttons simultaneously (4)
to discard all changes (NO)
Cancel: Press SELECT (3) to cancel the operation (CANCEL)
Table A. Factory default settings
Option
Menu
Default setting
1.
Frequency Mode
Receiver Setup
L-Band/1
2.
Frequency
Receiver Setup
950 MHz
3. Local Oscillator #1
Receiver Setup
9.750 GHz
4. Local Oscillator #2
Receiver Setup
10.600 GHz
5. Crossover
Receiver Setup
11.700 GHz
6. Polarization
Receiver Setup
H (Horizontal)
7.
FEC Rate
Receiver Setup
7/8
8. Symbol Rate
Receiver Setup
28.3465 Msymbols/sec.
9. Network ID
Receiver Setup
1
10. Lock Level
User Setup
0
11. Bouquet ID
User Setup
0
12. TV Audio
User Setup
Left + Right
13. Baud Rate
User Setup
9600
14. Aspect Ratio
User Setup
Normal
15. Local Time
User Setup
12:00 AM
16. IR Remote
User Setup
Disabled (OFF)
17. Date Format
User Setup
US
18. Video Standard
User Setup
AUTO
19. Subtitles Language
User Setup
Arabic
20. Password
User Setup
1 2 3 4
21. Search Mode
Search Setup
OFF
22. Search Type
Search Setup
Frequency
23. Lower Range
Search Setup
950 MHz
24. Upper Range
Search Setup
2150 MHz
25. IQ Select
Search Setup
Automatic
WARNING! Saved settings are automatically restored when the receiver is
restarted after AC power is switched off or interrupted. Upon restarting,
the receiver defaults to the virtual channel previously displayed for more
than 20 seconds after exiting from menus (see also
…
About saving
changes in the Installation and Operation Guide).