CF4 Water Evacuation Failure
1.
Detection
Chamber full switch did not open in 1 minute after drain pump turned ON.
2.
Cause
Defective chamber full switch
Clogged drain
Defective drain pump
CF7 Cycle Aborted or Interrupted
1.
Detection
Stop button pressed or power failure
2.
Cause
Stop button pressed or power failure
CF9 Software or PCB Failure
1.
Detection
The unit is running a cycle for more than 3 hours
2.
Cause
Defective PCB and/or software failure.
CF11 No Detergent Flow
1.
Detection
The flow switch did not detect detergent flowing. CF11 will not be displayed if the flow
switch doesn’t detect detergent during the rinse phase of the cycle. However, “no detergent”
will be displayed when the next cycle is selected.
2.
Cause
No detergent
Defective flow switch
CF14 Bad Flow Switch
1.
Detection
After the second dosing during the wash phase of the cycle, the flow switch did not turn
OFF after a 15 second timeout.
2.
Cause
Flow switch stuck ON.
CF15 Chamber Overflow
1.
Detection
The overflow switch did not turn OFF after 30 seconds of the drain pump running.
2.
Cause
Defective overflow switch
Clogged drain