Part 1
- 25 -
All rights reserved. Reproduction - in whole or in part - only with the express written permission of the editor.
004.139.00-en
6.
Mode of operation
:
REMOTE
Silent diagnostic
:
Yes
High level fault
The fault is displayed on the screen and an-
nounced by the buzzer in the control cabinet
In addition, the control system is switched off.
Optional shutdown of the engine is also possi-
ble.
-
Activate "QUIT" on the remote
control box (Fig. 1)
once.
The buzzer stops sounding (if
not switched off manually, the
buzzer will be stopped auto-
matically after 60 seconds).
The message continues to be
displayed and can be read in
no hurry.
-
Depress the "QUIT" key on the
control cabinet (Fig. 2).
The fault message is definitely
acknowledged.
The message is deleted from
the display and logged in the
faults list.
ATTENTION:
RISK OF ACCIDENT AND DAMAGE
After shut-off by a high level fault,
the control system and, if applicable,
also the drive engine must be restarted.
ñ It is absolutely vital to have a
severe fault rectified before re-
starting. There is otherwise the
risk of irreparable damage to the
machine.
Important:
High levelfaults can only be acknowl-
edged with the "QUIT" key on the
control cabinet irrespective of the
selected mode LOCAL or REMOTE.